[v6,06/12] arm: mvebu: clearfog: Add SATA mode flags

Message ID 20200323202140.309602-7-mrjoel@lixil.net
State Accepted
Commit 009d4cfcf27f9b3bc5fbb2f53731e6c59015aa33
Headers show
Series ClearFog Base static variant support | expand

Commit Message

Joel Johnson March 23, 2020, 8:21 p.m. UTC
The mPCIe slots on ClearFog Pro and ClearFog Base may be alternately
configured for SATA usage.

Signed-off-by: Joel Johnson <mrjoel at lixil.net>
Reviewed-by: Stefan Roese <sr at denx.de>

---

v2 changes:
  - fixed help indentation
v3 changes:
  - none
v4 changes:
  - adjust static SerDes configuration at runtime instead of #ifdef
  - add setting of swap_rx for SATA (as yet untested on hardware)
v5 changes:
  - make independent of runtime detection
v6 change:
  - remove code side double check of config consistency

---
 board/solidrun/clearfog/Kconfig    | 17 +++++++++++++++++
 board/solidrun/clearfog/clearfog.c | 14 ++++++++++++++
 2 files changed, 31 insertions(+)
diff mbox series

Patch

diff --git a/board/solidrun/clearfog/Kconfig b/board/solidrun/clearfog/Kconfig
index c910e17093..44224d903d 100644
--- a/board/solidrun/clearfog/Kconfig
+++ b/board/solidrun/clearfog/Kconfig
@@ -15,6 +15,23 @@  config TARGET_CLEARFOG_BASE
 	  detection via additional EEPROM hardware. This option enables selecting
 	  the Base variant for older hardware revisions.
 
+config CLEARFOG_CON3_SATA
+	bool "Use CON3 slot in SATA mode"
+	help
+	  Use the CON3 port with SATA protocol instead of the default PCIe.
+	  The ClearFog port allows usage of either mSATA or miniPCIe
+	  modules, but the desired protocol must be configured at build
+	  time since it affects the SerDes topology layout.
+
+config CLEARFOG_CON2_SATA
+	bool "Use CON2 slot in SATA mode"
+	depends on !TARGET_CLEARFOG_BASE
+	help
+	  Use the CON2 port with SATA protocol instead of the default PCIe.
+	  The ClearFog port allows usage of either mSATA or miniPCIe
+	  modules, but the desired protocol must be configured at build
+	  time since it affects the SerDes topology layout.
+
 config CLEARFOG_SFP_25GB
 	bool "Enable 2.5 Gbps mode for SFP"
 	help
diff --git a/board/solidrun/clearfog/clearfog.c b/board/solidrun/clearfog/clearfog.c
index 8f3e5dc6a3..fd9bd95a15 100644
--- a/board/solidrun/clearfog/clearfog.c
+++ b/board/solidrun/clearfog/clearfog.c
@@ -67,6 +67,20 @@  int hws_board_topology_load(struct serdes_map **serdes_map_array, u8 *count)
 	if (IS_ENABLED(CONFIG_CLEARFOG_SFP_25GB))
 		board_serdes_map[5].serdes_speed = SERDES_SPEED_3_125_GBPS;
 
+	if (IS_ENABLED(CONFIG_CLEARFOG_CON2_SATA)) {
+		board_serdes_map[4].serdes_type = SATA2;
+		board_serdes_map[4].serdes_speed = SERDES_SPEED_3_GBPS;
+		board_serdes_map[4].serdes_mode = SERDES_DEFAULT_MODE;
+		board_serdes_map[4].swap_rx = 1;
+	}
+
+	if (IS_ENABLED(CONFIG_CLEARFOG_CON3_SATA)) {
+		board_serdes_map[2].serdes_type = SATA1;
+		board_serdes_map[2].serdes_speed = SERDES_SPEED_3_GBPS;
+		board_serdes_map[2].serdes_mode = SERDES_DEFAULT_MODE;
+		board_serdes_map[2].swap_rx = 1;
+	}
+
 	/* Apply runtime detection changes */
 	if (sr_product_is(&cf_tlv_data, "Clearfog GTR")) {
 		board_serdes_map[0].serdes_type = PEX0;