diff mbox series

[5.15,536/913] power: ab8500_chargalg: Use CLOCK_MONOTONIC

Message ID 20220405070355.916061620@linuxfoundation.org
State New
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman April 5, 2022, 7:26 a.m. UTC
From: Linus Walleij <linus.walleij@linaro.org>

[ Upstream commit c22fca40522e2be8af168f3087d87d85e404ea72 ]

The HRTimer in the AB8500 charging code is using CLOCK_REALTIME
to set an alarm some hours forward in time +/- 5 min for a safety
timer.

I have observed that this will sometimes fire sporadically
early when charging a battery with the result that
charging stops.

As CLOCK_REALTIME can be subject to adjustments of time from
sources such as NTP, this cannot be trusted and will likely
for example fire events if the clock is set forward some hours
by say NTP.

Use CLOCK_MONOTONIC as indicated in other instances and the
problem goes away. Also initialize the timer to REL mode
as this is what will be used later.

Fixes: 257107ae6b9b ("ab8500-chargalg: Use hrtimer")
Cc: Lee Jones <lee.jones@linaro.org>
Suggested-by: Matti Vaittinen <mazziesaccount@gmail.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Reviewed-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
---
 drivers/power/supply/ab8500_chargalg.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)
diff mbox series

Patch

diff --git a/drivers/power/supply/ab8500_chargalg.c b/drivers/power/supply/ab8500_chargalg.c
index ff4b26b1ceca..b809fa5abbba 100644
--- a/drivers/power/supply/ab8500_chargalg.c
+++ b/drivers/power/supply/ab8500_chargalg.c
@@ -2019,11 +2019,11 @@  static int ab8500_chargalg_probe(struct platform_device *pdev)
 	psy_cfg.drv_data = di;
 
 	/* Initilialize safety timer */
-	hrtimer_init(&di->safety_timer, CLOCK_REALTIME, HRTIMER_MODE_ABS);
+	hrtimer_init(&di->safety_timer, CLOCK_MONOTONIC, HRTIMER_MODE_REL);
 	di->safety_timer.function = ab8500_chargalg_safety_timer_expired;
 
 	/* Initilialize maintenance timer */
-	hrtimer_init(&di->maintenance_timer, CLOCK_REALTIME, HRTIMER_MODE_ABS);
+	hrtimer_init(&di->maintenance_timer, CLOCK_MONOTONIC, HRTIMER_MODE_REL);
 	di->maintenance_timer.function =
 		ab8500_chargalg_maintenance_timer_expired;