diff mbox series

[PULL,02/13] hw/scsi/scsi-generic: Fix io_timeout property not applying

Message ID 20240326154505.8300-3-philmd@linaro.org
State Accepted
Commit 7c7a9f578e4fb1adff7ac8d9acaaaedb87474e76
Headers show
Series [PULL,01/13] target/i386/tcg: Enable page walking from MMIO memory | expand

Commit Message

Philippe Mathieu-Daudé March 26, 2024, 3:44 p.m. UTC
From: Lorenz Brun <lorenz@brun.one>

The io_timeout property, introduced in c9b6609 (part of 6.0) is
silently overwritten by the hardcoded default value of 30 seconds
(DEFAULT_IO_TIMEOUT) in scsi_generic_realize because that function is
being called after the properties have already been applied.

The property definition already has a default value which is applied
correctly when no value is explicitly set, so we can just remove the
code which overrides the io_timeout completely.

This has been tested by stracing SG_IO operations with the io_timeout
property set and unset and now sets the timeout field in the ioctl
request to the proper value.

Fixes: c9b6609b69facad ("scsi: make io_timeout configurable")
Signed-off-by: Lorenz Brun <lorenz@brun.one>
Message-ID: <20240315145831.2531695-1-lorenz@brun.one>
Reviewed-by: Alex Bennée <alex.bennee@linaro.org>
Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
---
 hw/scsi/scsi-generic.c | 1 -
 1 file changed, 1 deletion(-)
diff mbox series

Patch

diff --git a/hw/scsi/scsi-generic.c b/hw/scsi/scsi-generic.c
index b7b04e1d63..ee945f87e3 100644
--- a/hw/scsi/scsi-generic.c
+++ b/hw/scsi/scsi-generic.c
@@ -752,7 +752,6 @@  static void scsi_generic_realize(SCSIDevice *s, Error **errp)
 
     /* Only used by scsi-block, but initialize it nevertheless to be clean.  */
     s->default_scsi_version = -1;
-    s->io_timeout = DEFAULT_IO_TIMEOUT;
     scsi_generic_read_device_inquiry(s);
 }