@@ -96,7 +96,7 @@ bool s390_cpu_tlb_fill(CPUState *cs, vaddr address, int size,
{
S390CPU *cpu = S390_CPU(cs);
- trigger_pgm_exception(&cpu->env, PGM_ADDRESSING, ILEN_AUTO);
+ trigger_pgm_exception(&cpu->env, PGM_ADDRESSING, ILEN_UNWIND);
/* On real machines this value is dropped into LowMem. Since this
is userland, simply put this someplace that cpu_loop can find it. */
cpu->env.__excp_addr = address;
@@ -179,24 +179,15 @@ bool s390_cpu_tlb_fill(CPUState *cs, vaddr address, int size,
stq_phys(env_cpu(env)->as,
env->psa + offsetof(LowCore, trans_exc_code), tec);
}
- trigger_pgm_exception(env, excp, ILEN_AUTO);
- cpu_restore_state(cs, retaddr, true);
/*
- * The ILC value for code accesses is undefined. The important
- * thing here is to *not* leave env->int_pgm_ilen set to ILEN_AUTO,
- * which would cause do_program_interrupt to attempt to read from
- * env->psw.addr again. C.f. the condition in trigger_page_fault,
- * but is not universally applied.
- *
- * ??? If we remove ILEN_AUTO, by moving the computation of ILEN
- * into cpu_restore_state, then we may remove this entirely.
+ * For data accesses, ILEN will be filled in from the unwind info,
+ * within cpu_loop_exit_restore. For code accesses, retaddr == 0,
+ * and so unwinding will not occur. However, ILEN is also undefined
+ * for that case -- we choose to set ILEN = 2.
*/
- if (access_type == MMU_INST_FETCH) {
- env->int_pgm_ilen = 2;
- }
-
- cpu_loop_exit(cs);
+ trigger_pgm_exception(env, excp, 2);
+ cpu_loop_exit_restore(cs, retaddr);
}
static void do_program_interrupt(CPUS390XState *env)