diff mbox series

[AUTOSEL,4.14,03/57] arm64: dts: uniphier: Add missing cooling device properties for CPUs

Message ID 20180915013223.179909-3-alexander.levin@microsoft.com
State New
Headers show
Series None | expand

Commit Message

Sasha Levin Sept. 15, 2018, 1:32 a.m. UTC
From: Viresh Kumar <viresh.kumar@linaro.org>


[ Upstream commit af0e09d0c6762e486b0eb5cc4737396964c34fad ]

The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>

Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>

Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>

---
 arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi | 2 ++
 1 file changed, 2 insertions(+)

-- 
2.17.1
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
index a29c279b6e8e..dba6f0ff8106 100644
--- a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
+++ b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
@@ -55,6 +55,7 @@ 
 			clocks = <&sys_clk 32>;
 			enable-method = "psci";
 			operating-points-v2 = <&cluster0_opp>;
+			#cooling-cells = <2>;
 		};
 
 		cpu2: cpu@100 {
@@ -73,6 +74,7 @@ 
 			clocks = <&sys_clk 33>;
 			enable-method = "psci";
 			operating-points-v2 = <&cluster1_opp>;
+			#cooling-cells = <2>;
 		};
 	};