Message ID | 4987649.31r3eYUQgx@rjwysocki.net |
---|---|
State | New |
Headers | show |
Series | thermal: core: Cosmetic updates | expand |
On 1/16/25 19:31, Rafael J. Wysocki wrote: > From: Rafael J. Wysocki <rafael.j.wysocki@intel.com> > > Move the regulation logic description from the bang_bang_trip_crossed() > kerneldoc to the preamble. > > No functional impact. > > Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> > --- > drivers/thermal/gov_bang_bang.c | 43 +++++++++++++++++++--------------------- > 1 file changed, 21 insertions(+), 22 deletions(-) > > --- a/drivers/thermal/gov_bang_bang.c > +++ b/drivers/thermal/gov_bang_bang.c > @@ -7,6 +7,27 @@ > * Based on step_wise.c with following Copyrights: > * Copyright (C) 2012 Intel Corp > * Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com> > + * > + * Regulation Logic: a two point regulation, deliver cooling state depending > + * on the previous state shown in this diagram: > + * > + * Fan: OFF ON > + * > + * | > + * | > + * trip_temp: +---->+ > + * | | ^ > + * | | | > + * | | Temperature > + * (trip_temp - hyst): +<----+ > + * | > + * | > + * | > + * > + * * If the fan is not running and temperature exceeds trip_temp, the fan > + * gets turned on. > + * * In case the fan is running, temperature must fall below > + * (trip_temp - hyst) so that the fan gets turned off again. > */ > > #include <linux/thermal.h> > @@ -38,28 +59,6 @@ > * @tz: thermal_zone_device > * @trip: the trip point > * @crossed_up: whether or not the trip has been crossed on the way up > - * > - * Regulation Logic: a two point regulation, deliver cooling state depending > - * on the previous state shown in this diagram: > - * > - * Fan: OFF ON > - * > - * | > - * | > - * trip_temp: +---->+ > - * | | ^ > - * | | | > - * | | Temperature > - * (trip_temp - hyst): +<----+ > - * | > - * | > - * | > - * > - * * If the fan is not running and temperature exceeds trip_temp, the fan > - * gets turned on. > - * * In case the fan is running, temperature must fall below > - * (trip_temp - hyst) so that the fan gets turned off again. > - * > */ > static void bang_bang_trip_crossed(struct thermal_zone_device *tz, > const struct thermal_trip *trip, > > > Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
--- a/drivers/thermal/gov_bang_bang.c +++ b/drivers/thermal/gov_bang_bang.c @@ -7,6 +7,27 @@ * Based on step_wise.c with following Copyrights: * Copyright (C) 2012 Intel Corp * Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com> + * + * Regulation Logic: a two point regulation, deliver cooling state depending + * on the previous state shown in this diagram: + * + * Fan: OFF ON + * + * | + * | + * trip_temp: +---->+ + * | | ^ + * | | | + * | | Temperature + * (trip_temp - hyst): +<----+ + * | + * | + * | + * + * * If the fan is not running and temperature exceeds trip_temp, the fan + * gets turned on. + * * In case the fan is running, temperature must fall below + * (trip_temp - hyst) so that the fan gets turned off again. */ #include <linux/thermal.h> @@ -38,28 +59,6 @@ * @tz: thermal_zone_device * @trip: the trip point * @crossed_up: whether or not the trip has been crossed on the way up - * - * Regulation Logic: a two point regulation, deliver cooling state depending - * on the previous state shown in this diagram: - * - * Fan: OFF ON - * - * | - * | - * trip_temp: +---->+ - * | | ^ - * | | | - * | | Temperature - * (trip_temp - hyst): +<----+ - * | - * | - * | - * - * * If the fan is not running and temperature exceeds trip_temp, the fan - * gets turned on. - * * In case the fan is running, temperature must fall below - * (trip_temp - hyst) so that the fan gets turned off again. - * */ static void bang_bang_trip_crossed(struct thermal_zone_device *tz, const struct thermal_trip *trip,