@@ -467,7 +467,7 @@ static void bq25890_update_state(struct bq25890_device *bq,
/* update state in case we lost an interrupt */
__bq25890_handle_irq(bq);
*state = bq->state;
- do_adc_conv = !state->online && bq25890_is_adc_property(psp);
+ do_adc_conv = (!state->online || state->hiz) && bq25890_is_adc_property(psp);
if (do_adc_conv)
bq25890_field_write(bq, F_CONV_START, 1);
mutex_unlock(&bq->lock);
@@ -956,7 +956,7 @@ static int bq25890_hw_init(struct bq25890_device *bq)
}
/* Configure ADC for continuous conversions when charging */
- ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
+ ret = bq25890_field_write(bq, F_CONV_RATE, bq->state.online && !bq->state.hiz);
if (ret < 0) {
dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
return ret;
The code to check if F_CONV_RATE has been set, or if a manual ADC conversion needs to be triggered, as well as the code to set the initial F_CONV_RATE value at probe both where not taking HiZ mode into account. Add checks for this. Signed-off-by: Hans de Goede <hdegoede@redhat.com> --- drivers/power/supply/bq25890_charger.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)