diff mbox series

[2/3] power: supply: max17042: remove duplicated STATUS bit defines

Message ID 20210816082716.21193-2-krzysztof.kozlowski@canonical.com
State Accepted
Commit 22b6907caf1191f54dd0f4568414076ab479b7d3
Headers show
Series [1/3] power: supply: max17042: handle fails of reading status register | expand

Commit Message

Krzysztof Kozlowski Aug. 16, 2021, 8:27 a.m. UTC
All bits of STATUS register are already defined (see STATUS_SMN_BIT and
further) so there is no need to define status SoC threshold min/max
values one more time.

Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
---
 drivers/power/supply/max17042_battery.c | 5 +----
 1 file changed, 1 insertion(+), 4 deletions(-)
diff mbox series

Patch

diff --git a/drivers/power/supply/max17042_battery.c b/drivers/power/supply/max17042_battery.c
index 858ae97600d4..936e43fb710b 100644
--- a/drivers/power/supply/max17042_battery.c
+++ b/drivers/power/supply/max17042_battery.c
@@ -36,8 +36,6 @@ 
 
 /* Interrupt mask bits */
 #define CONFIG_ALRT_BIT_ENBL	(1 << 2)
-#define STATUS_INTR_SOCMIN_BIT	(1 << 10)
-#define STATUS_INTR_SOCMAX_BIT	(1 << 14)
 
 #define VFSOC0_LOCK		0x0000
 #define VFSOC0_UNLOCK		0x0080
@@ -875,8 +873,7 @@  static irqreturn_t max17042_thread_handler(int id, void *dev)
 	if (ret)
 		return IRQ_HANDLED;
 
-	if ((val & STATUS_INTR_SOCMIN_BIT) ||
-		(val & STATUS_INTR_SOCMAX_BIT)) {
+	if ((val & STATUS_SMN_BIT) || (val & STATUS_SMX_BIT)) {
 		dev_info(&chip->client->dev, "SOC threshold INTR\n");
 		max17042_set_soc_threshold(chip, 1);
 	}