diff mbox series

[v4,14/14] arm64: dts: Convert to the hierarchical CPU topology layout for MSM8916

Message ID 20191211154343.29765-15-ulf.hansson@linaro.org
State Superseded
Headers show
Series cpuidle: psci: Support hierarchical CPU arrangement | expand

Commit Message

Ulf Hansson Dec. 11, 2019, 3:43 p.m. UTC
To enable the OS to better support PSCI OS initiated CPU suspend mode,
let's convert from the flattened layout to the hierarchical layout.

In the hierarchical layout, let's create a power domain provider per CPU
and describe the idle states for each CPU inside the power domain provider
node. To group the CPUs into a cluster, let's add another power domain
provider and make it act as the master domain. Note that, the CPU's idle
states remains compatible with "arm,idle-state", while the cluster's idle
state becomes compatible with "domain-idle-state".

Co-developed-by: Lina Iyer <lina.iyer@linaro.org>
Signed-off-by: Lina Iyer <lina.iyer@linaro.org>

Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>

---

Changes in v4:
	- None.

---
 arch/arm64/boot/dts/qcom/msm8916.dtsi | 57 +++++++++++++++++++++++++--
 1 file changed, 53 insertions(+), 4 deletions(-)

-- 
2.17.1

Comments

Ulf Hansson Dec. 19, 2019, 3:48 p.m. UTC | #1
On Thu, 19 Dec 2019 at 15:34, Sudeep Holla <sudeep.holla@arm.com> wrote:
>

> On Wed, Dec 11, 2019 at 04:43:43PM +0100, Ulf Hansson wrote:

> > To enable the OS to better support PSCI OS initiated CPU suspend mode,

> > let's convert from the flattened layout to the hierarchical layout.

> >

> > In the hierarchical layout, let's create a power domain provider per CPU

> > and describe the idle states for each CPU inside the power domain provider

> > node. To group the CPUs into a cluster, let's add another power domain

> > provider and make it act as the master domain. Note that, the CPU's idle

> > states remains compatible with "arm,idle-state", while the cluster's idle

> > state becomes compatible with "domain-idle-state".

> >

> > Co-developed-by: Lina Iyer <lina.iyer@linaro.org>

> > Signed-off-by: Lina Iyer <lina.iyer@linaro.org>

> > Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>

> > ---

> >

> > Changes in v4:

> >       - None.

> >

> > ---

> >  arch/arm64/boot/dts/qcom/msm8916.dtsi | 57 +++++++++++++++++++++++++--

> >  1 file changed, 53 insertions(+), 4 deletions(-)

> >

> > diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi b/arch/arm64/boot/dts/qcom/msm8916.dtsi

> > index 8686e101905c..282c36c8fa3b 100644

> > --- a/arch/arm64/boot/dts/qcom/msm8916.dtsi

> > +++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi

> > @@ -102,10 +102,11 @@

> >                       reg = <0x0>;

> >                       next-level-cache = <&L2_0>;

> >                       enable-method = "psci";

> > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> >                       clocks = <&apcs>;

> >                       operating-points-v2 = <&cpu_opp_table>;

> >                       #cooling-cells = <2>;

> > +                     power-domains = <&CPU_PD0>;

> > +                     power-domain-names = "psci";

> >               };

> >

> >               CPU1: cpu@1 {

> > @@ -114,10 +115,11 @@

> >                       reg = <0x1>;

> >                       next-level-cache = <&L2_0>;

> >                       enable-method = "psci";

> > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> >                       clocks = <&apcs>;

> >                       operating-points-v2 = <&cpu_opp_table>;

> >                       #cooling-cells = <2>;

> > +                     power-domains = <&CPU_PD1>;

> > +                     power-domain-names = "psci";

> >               };

> >

> >               CPU2: cpu@2 {

> > @@ -126,10 +128,11 @@

> >                       reg = <0x2>;

> >                       next-level-cache = <&L2_0>;

> >                       enable-method = "psci";

> > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> >                       clocks = <&apcs>;

> >                       operating-points-v2 = <&cpu_opp_table>;

> >                       #cooling-cells = <2>;

> > +                     power-domains = <&CPU_PD2>;

> > +                     power-domain-names = "psci";

> >               };

> >

> >               CPU3: cpu@3 {

> > @@ -138,10 +141,11 @@

> >                       reg = <0x3>;

> >                       next-level-cache = <&L2_0>;

> >                       enable-method = "psci";

> > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> >                       clocks = <&apcs>;

> >                       operating-points-v2 = <&cpu_opp_table>;

> >                       #cooling-cells = <2>;

> > +                     power-domains = <&CPU_PD3>;

> > +                     power-domain-names = "psci";

> >               };

> >

> >               L2_0: l2-cache {

> > @@ -161,12 +165,57 @@

> >                               min-residency-us = <2000>;

> >                               local-timer-stop;

> >                       };

> > +

> > +                     CLUSTER_RET: cluster-retention {

> > +                             compatible = "domain-idle-state";

> > +                             arm,psci-suspend-param = <0x41000012>;

>

> If I followed the thread correctly, we are now just using the param as is

> without any extra logic like ORing like before. i.e. The domain state

> parameter overrides the any param below it in the hierarchy.

>

> If that's correct, then


That's correct!

> Acked-by: Sudeep Holla <sudeep.holla@arm.com>


Thanks!

Kind regards
Uffe
Sudeep Holla Dec. 19, 2019, 5:58 p.m. UTC | #2
On Thu, Dec 19, 2019 at 04:48:47PM +0100, Ulf Hansson wrote:
> On Thu, 19 Dec 2019 at 15:34, Sudeep Holla <sudeep.holla@arm.com> wrote:

> >

> > On Wed, Dec 11, 2019 at 04:43:43PM +0100, Ulf Hansson wrote:

> > > To enable the OS to better support PSCI OS initiated CPU suspend mode,

> > > let's convert from the flattened layout to the hierarchical layout.

> > >

> > > In the hierarchical layout, let's create a power domain provider per CPU

> > > and describe the idle states for each CPU inside the power domain provider

> > > node. To group the CPUs into a cluster, let's add another power domain

> > > provider and make it act as the master domain. Note that, the CPU's idle

> > > states remains compatible with "arm,idle-state", while the cluster's idle

> > > state becomes compatible with "domain-idle-state".

> > >

> > > Co-developed-by: Lina Iyer <lina.iyer@linaro.org>

> > > Signed-off-by: Lina Iyer <lina.iyer@linaro.org>

> > > Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>

> > > ---

> > >

> > > Changes in v4:

> > >       - None.

> > >

> > > ---

> > >  arch/arm64/boot/dts/qcom/msm8916.dtsi | 57 +++++++++++++++++++++++++--

> > >  1 file changed, 53 insertions(+), 4 deletions(-)

> > >

> > > diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi b/arch/arm64/boot/dts/qcom/msm8916.dtsi

> > > index 8686e101905c..282c36c8fa3b 100644

> > > --- a/arch/arm64/boot/dts/qcom/msm8916.dtsi

> > > +++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi

> > > @@ -102,10 +102,11 @@

> > >                       reg = <0x0>;

> > >                       next-level-cache = <&L2_0>;

> > >                       enable-method = "psci";

> > > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> > >                       clocks = <&apcs>;

> > >                       operating-points-v2 = <&cpu_opp_table>;

> > >                       #cooling-cells = <2>;

> > > +                     power-domains = <&CPU_PD0>;

> > > +                     power-domain-names = "psci";

> > >               };

> > >

> > >               CPU1: cpu@1 {

> > > @@ -114,10 +115,11 @@

> > >                       reg = <0x1>;

> > >                       next-level-cache = <&L2_0>;

> > >                       enable-method = "psci";

> > > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> > >                       clocks = <&apcs>;

> > >                       operating-points-v2 = <&cpu_opp_table>;

> > >                       #cooling-cells = <2>;

> > > +                     power-domains = <&CPU_PD1>;

> > > +                     power-domain-names = "psci";

> > >               };

> > >

> > >               CPU2: cpu@2 {

> > > @@ -126,10 +128,11 @@

> > >                       reg = <0x2>;

> > >                       next-level-cache = <&L2_0>;

> > >                       enable-method = "psci";

> > > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> > >                       clocks = <&apcs>;

> > >                       operating-points-v2 = <&cpu_opp_table>;

> > >                       #cooling-cells = <2>;

> > > +                     power-domains = <&CPU_PD2>;

> > > +                     power-domain-names = "psci";

> > >               };

> > >

> > >               CPU3: cpu@3 {

> > > @@ -138,10 +141,11 @@

> > >                       reg = <0x3>;

> > >                       next-level-cache = <&L2_0>;

> > >                       enable-method = "psci";

> > > -                     cpu-idle-states = <&CPU_SLEEP_0>;

> > >                       clocks = <&apcs>;

> > >                       operating-points-v2 = <&cpu_opp_table>;

> > >                       #cooling-cells = <2>;

> > > +                     power-domains = <&CPU_PD3>;

> > > +                     power-domain-names = "psci";

> > >               };

> > >

> > >               L2_0: l2-cache {

> > > @@ -161,12 +165,57 @@

> > >                               min-residency-us = <2000>;

> > >                               local-timer-stop;

> > >                       };

> > > +

> > > +                     CLUSTER_RET: cluster-retention {

> > > +                             compatible = "domain-idle-state";

> > > +                             arm,psci-suspend-param = <0x41000012>;

> >

> > If I followed the thread correctly, we are now just using the param as is

> > without any extra logic like ORing like before. i.e. The domain state

> > parameter overrides the any param below it in the hierarchy.

> >

> > If that's correct, then

>

> That's correct!

>


Thanks for the confirmation.

--
Regards,
Sudeep
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi b/arch/arm64/boot/dts/qcom/msm8916.dtsi
index 8686e101905c..282c36c8fa3b 100644
--- a/arch/arm64/boot/dts/qcom/msm8916.dtsi
+++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi
@@ -102,10 +102,11 @@ 
 			reg = <0x0>;
 			next-level-cache = <&L2_0>;
 			enable-method = "psci";
-			cpu-idle-states = <&CPU_SLEEP_0>;
 			clocks = <&apcs>;
 			operating-points-v2 = <&cpu_opp_table>;
 			#cooling-cells = <2>;
+			power-domains = <&CPU_PD0>;
+			power-domain-names = "psci";
 		};
 
 		CPU1: cpu@1 {
@@ -114,10 +115,11 @@ 
 			reg = <0x1>;
 			next-level-cache = <&L2_0>;
 			enable-method = "psci";
-			cpu-idle-states = <&CPU_SLEEP_0>;
 			clocks = <&apcs>;
 			operating-points-v2 = <&cpu_opp_table>;
 			#cooling-cells = <2>;
+			power-domains = <&CPU_PD1>;
+			power-domain-names = "psci";
 		};
 
 		CPU2: cpu@2 {
@@ -126,10 +128,11 @@ 
 			reg = <0x2>;
 			next-level-cache = <&L2_0>;
 			enable-method = "psci";
-			cpu-idle-states = <&CPU_SLEEP_0>;
 			clocks = <&apcs>;
 			operating-points-v2 = <&cpu_opp_table>;
 			#cooling-cells = <2>;
+			power-domains = <&CPU_PD2>;
+			power-domain-names = "psci";
 		};
 
 		CPU3: cpu@3 {
@@ -138,10 +141,11 @@ 
 			reg = <0x3>;
 			next-level-cache = <&L2_0>;
 			enable-method = "psci";
-			cpu-idle-states = <&CPU_SLEEP_0>;
 			clocks = <&apcs>;
 			operating-points-v2 = <&cpu_opp_table>;
 			#cooling-cells = <2>;
+			power-domains = <&CPU_PD3>;
+			power-domain-names = "psci";
 		};
 
 		L2_0: l2-cache {
@@ -161,12 +165,57 @@ 
 				min-residency-us = <2000>;
 				local-timer-stop;
 			};
+
+			CLUSTER_RET: cluster-retention {
+				compatible = "domain-idle-state";
+				arm,psci-suspend-param = <0x41000012>;
+				entry-latency-us = <500>;
+				exit-latency-us = <500>;
+				min-residency-us = <2000>;
+			};
+
+			CLUSTER_PWRDN: cluster-gdhs {
+				compatible = "domain-idle-state";
+				arm,psci-suspend-param = <0x41000032>;
+				entry-latency-us = <2000>;
+				exit-latency-us = <2000>;
+				min-residency-us = <6000>;
+			};
 		};
 	};
 
 	psci {
 		compatible = "arm,psci-1.0";
 		method = "smc";
+
+		CPU_PD0: cpu-pd0 {
+			#power-domain-cells = <0>;
+			power-domains = <&CLUSTER_PD>;
+			domain-idle-states = <&CPU_SLEEP_0>;
+		};
+
+		CPU_PD1: cpu-pd1 {
+			#power-domain-cells = <0>;
+			power-domains = <&CLUSTER_PD>;
+			domain-idle-states = <&CPU_SLEEP_0>;
+		};
+
+		CPU_PD2: cpu-pd2 {
+			#power-domain-cells = <0>;
+			power-domains = <&CLUSTER_PD>;
+			domain-idle-states = <&CPU_SLEEP_0>;
+		};
+
+		CPU_PD3: cpu-pd3 {
+			#power-domain-cells = <0>;
+			power-domains = <&CLUSTER_PD>;
+			domain-idle-states = <&CPU_SLEEP_0>;
+		};
+
+		CLUSTER_PD: cluster-pd {
+			#power-domain-cells = <0>;
+			domain-idle-states = <&CLUSTER_RET>, <&CLUSTER_PWRDN>;
+		};
 	};
 
 	pmu {