From patchwork Tue Mar 8 19:35:22 2022 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: Henning Schild X-Patchwork-Id: 551018 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on aws-us-west-2-korg-lkml-1.web.codeaurora.org Received: from vger.kernel.org (vger.kernel.org [23.128.96.18]) by smtp.lore.kernel.org (Postfix) with ESMTP id A5FA9C4167D for ; Tue, 8 Mar 2022 19:35:45 +0000 (UTC) Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1350036AbiCHTgk (ORCPT ); Tue, 8 Mar 2022 14:36:40 -0500 Received: from lindbergh.monkeyblade.net ([23.128.96.19]:41016 "EHLO lindbergh.monkeyblade.net" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1350029AbiCHTgi (ORCPT ); Tue, 8 Mar 2022 14:36:38 -0500 Received: from EUR04-VI1-obe.outbound.protection.outlook.com (mail-eopbgr80082.outbound.protection.outlook.com [40.107.8.82]) by lindbergh.monkeyblade.net (Postfix) with ESMTPS id 5256054BC0; Tue, 8 Mar 2022 11:35:40 -0800 (PST) ARC-Seal: i=1; a=rsa-sha256; s=arcselector9901; d=microsoft.com; cv=none; b=Bws+cYYERIEykc1PlRfUOlejT4RZ9rt4nNsOdQRaDZddYNcNMoqRNYwzKEC7GF7cjMC7LC8s2EMnbHLMLB5wtwL0hnfmTHscO7pFbaSfiAeSiRVx6wzk8p1av1hWjZ0VXSCq+tFB+/v54GsnCQPnYRwt+vKDK5BWtH0vg2CNWqAwayOma0t2GB9+Q2YS59hVbGw+8wMMaUNO5mFy5IBpZFkxwSfo3zazglBmi0DtQShZooVm7w0/kjH986/4mUcDw1otIJkpgo488wnVI6XQsk0keIciKmtjw3Mz+QzUkwlT/6DvkNzzKBXBKZbreyBhviM+pIEONHBbvGCzXzkC4w== ARC-Message-Signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector9901; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-AntiSpam-MessageData-ChunkCount:X-MS-Exchange-AntiSpam-MessageData-0:X-MS-Exchange-AntiSpam-MessageData-1; bh=4P/pZiBUzjfO1TSlGB10tzMEhZLzoCZVJDPflngopzw=; b=d/hWoh5JufIl/rn2NXUCO8BPeZor/qqYwNfSGJavPmyYDOuVtPDRFtt/oLdlIb9VN7NGQHEFq18iCJFOX4ebkvPOEGv/3t+4RDCCoo2Lh6gcbgo08j3tfJLYdbdk1Cf5rP9dX0lkYthipiKq4rT09NfYqLuuh9NrfRMKgEj4UVC1uCeLWMEZawjnbqj986CCtKVwvniec0WsW6g4/fBO5SA60WeV1F7Yi8VW6YCW/pciE57G1qgX3nQJwimDQ2+E/fqEnbJP80vGsbTOoVjXXFTDemqlYf9ak1Lr9tDHkyC7YU53efVq5Hno8yZqmKmp3OediMDa7md5BiFebNYLBg== ARC-Authentication-Results: i=1; mx.microsoft.com 1; spf=pass (sender ip is 194.138.21.73) smtp.rcpttodomain=linux.intel.com smtp.mailfrom=siemens.com; dmarc=pass (p=none sp=none pct=100) action=none header.from=siemens.com; dkim=none (message not signed); arc=none DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=siemens.com; s=selector2; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=4P/pZiBUzjfO1TSlGB10tzMEhZLzoCZVJDPflngopzw=; b=LuFWKqgQB4lv0NjVQ4DwpDSLYMLffW2cGlwseGB3ESVNVfEVhnYILmKkaVQ7s2UR10B0d5iTQKC1mixjnKDwmjHPZ2tMGcwcD39xuZIuawWPEIQqz6Ug1EsSoPSfxVwFtk8OEYfP1GGjZ2CrjNZ+BZ7xSpxbwVQNGV7fVa08WGqQaZ9hUoSPqx3UDD8Ue5ZOmY+yZ/kAqJTBOg81e9u7mebjc7+D9Noa/iWX6/HaqeSc/wDTCE3TiIDSYmLc/j7rfSCYwYKr0jfOR0G3sfQJozHoDzKP2r4v6IfBM5GCW+kuIgOMatT2FuuXnt2knlc29z5KzLDpStYkxoPLfMksKg== Received: from DU2PR04CA0039.eurprd04.prod.outlook.com (2603:10a6:10:234::14) by VI1PR10MB2672.EURPRD10.PROD.OUTLOOK.COM (2603:10a6:803:e3::20) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.5038.16; Tue, 8 Mar 2022 19:35:36 +0000 Received: from DB5EUR01FT053.eop-EUR01.prod.protection.outlook.com (2603:10a6:10:234:cafe::7b) by DU2PR04CA0039.outlook.office365.com (2603:10a6:10:234::14) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.5038.14 via Frontend Transport; Tue, 8 Mar 2022 19:35:36 +0000 X-MS-Exchange-Authentication-Results: spf=pass (sender IP is 194.138.21.73) smtp.mailfrom=siemens.com; dkim=none (message not signed) header.d=none;dmarc=pass action=none header.from=siemens.com; Received-SPF: Pass (protection.outlook.com: domain of siemens.com designates 194.138.21.73 as permitted sender) receiver=protection.outlook.com; client-ip=194.138.21.73; helo=hybrid.siemens.com; Received: from hybrid.siemens.com (194.138.21.73) by DB5EUR01FT053.mail.protection.outlook.com (10.152.5.159) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256) id 15.20.5038.14 via Frontend Transport; Tue, 8 Mar 2022 19:35:36 +0000 Received: from DEMCHDC89XA.ad011.siemens.net (139.25.226.103) by DEMCHDC9SNA.ad011.siemens.net (194.138.21.73) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256) id 15.1.2375.18; Tue, 8 Mar 2022 20:35:35 +0100 Received: from localhost.localdomain (167.87.32.5) by DEMCHDC89XA.ad011.siemens.net (139.25.226.103) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256) id 15.1.2375.18; Tue, 8 Mar 2022 20:35:35 +0100 From: Henning Schild To: Andy Shevchenko CC: Mark Gross , Wim Van Sebroeck , Guenter Roeck , , , , , Enrico Weigelt , Gerd Haeussler , Henning Schild Subject: [PATCH 2/2] leds: simatic-ipc-leds-gpio: add GPIO version of Siemens driver Date: Tue, 8 Mar 2022 20:35:22 +0100 Message-ID: <20220308193522.26696-3-henning.schild@siemens.com> X-Mailer: git-send-email 2.34.1 In-Reply-To: <20220308193522.26696-1-henning.schild@siemens.com> References: <20220131151346.45792-1-andriy.shevchenko@linux.intel.com> <20220308193522.26696-1-henning.schild@siemens.com> MIME-Version: 1.0 X-Originating-IP: [167.87.32.5] X-ClientProxiedBy: DEMCHDC8A0A.ad011.siemens.net (139.25.226.106) To DEMCHDC89XA.ad011.siemens.net (139.25.226.103) X-TM-AS-Product-Ver: SMEX-14.0.0.3080-8.6.1018-26680.007 X-TM-AS-Result: No-10--8.549500-8.000000 X-TMASE-MatchedRID: cFv5M0vAheta0fQUqAzR3e3DB3+/CehKE34mKqQRielKtJAbYAprczMD HwdijHSHBph69XjMbdmAecOigRAlta3aC25avUuaSwG3KDMI8e8i0gNgcOfRtoY5QY8KaJtTdFS hyLDxof9WtqPVHVdXmMRLhY4YFk6tSpLsaBDNZu9NiTj8hqiOOFCmyOJJq7C0TvKpZzlxUs+NY/ pqxovzxSiho3Yx5jAibuUFf/ftHinvTdvFoUrn/1PN/NUwB3i/MNC3Xj2tG7LfSQNpZkETVDFcf 92WG8u/WaGFzkcqBkl79xCSa3QbsXjfaEUd3sukxtBcxzOivxZ8Ce7b2ZEcq1N7BS4nAhYVhVDn kfzD7uYOkJQR4QWbsMRf0/tVPfcblOSYZlnQW/AiTMW5ZqQa6FP8N0xmYb7azNIobH2DzGFVogW RsEaR/msoHwKHdDo36dAjf9Fk9GpL0qen/wedYdoP5MB/iAfxlCv0a7truiKeAiCmPx4NwBnUJ0 Ek6yhjxEHRux+uk8jHUU+U0ACZwHqMCzY77a4j0Vld27YPhBhkd0fT8AYHwRVt3i2HPS02nqg/V rSZEiM= X-TM-AS-User-Approved-Sender: No X-TM-AS-User-Blocked-Sender: No X-TMASE-Result: 10--8.549500-8.000000 X-TMASE-Version: SMEX-14.0.0.3080-8.6.1018-26680.007 X-TM-SNTS-SMTP: BD2C0BDDC919A38E5A4C1749FD5AAE3AB33D97C4C9A76F87F2E99345013E8B8D2000:8 X-EOPAttributedMessage: 0 X-MS-PublicTrafficType: Email X-MS-Office365-Filtering-Correlation-Id: 60eae7c2-d319-4d37-299b-08da013ad1b0 X-MS-TrafficTypeDiagnostic: VI1PR10MB2672:EE_ X-Microsoft-Antispam-PRVS: X-MS-Exchange-SenderADCheck: 1 X-MS-Exchange-AntiSpam-Relay: 0 X-Microsoft-Antispam: BCL:0; X-Microsoft-Antispam-Message-Info: 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 X-Forefront-Antispam-Report: CIP:194.138.21.73; CTRY:DE; LANG:en; SCL:1; SRV:; IPV:NLI; SFV:NSPM; H:hybrid.siemens.com; PTR:InfoDomainNonexistent; CAT:NONE; SFS:(13230001)(4636009)(40470700004)(46966006)(36840700001)(2616005)(16526019)(40460700003)(82960400001)(2906002)(82310400004)(81166007)(5660300002)(30864003)(36756003)(356005)(86362001)(8936002)(44832011)(316002)(6916009)(107886003)(956004)(336012)(186003)(26005)(508600001)(54906003)(6666004)(1076003)(47076005)(8676002)(36860700001)(4326008)(83380400001)(70586007)(70206006)(36900700001); DIR:OUT; SFP:1101; X-OriginatorOrg: siemens.com X-MS-Exchange-CrossTenant-OriginalArrivalTime: 08 Mar 2022 19:35:36.3346 (UTC) X-MS-Exchange-CrossTenant-Network-Message-Id: 60eae7c2-d319-4d37-299b-08da013ad1b0 X-MS-Exchange-CrossTenant-Id: 38ae3bcd-9579-4fd4-adda-b42e1495d55a X-MS-Exchange-CrossTenant-OriginalAttributedTenantConnectingIp: TenantId=38ae3bcd-9579-4fd4-adda-b42e1495d55a; Ip=[194.138.21.73]; Helo=[hybrid.siemens.com] X-MS-Exchange-CrossTenant-AuthSource: DB5EUR01FT053.eop-EUR01.prod.protection.outlook.com X-MS-Exchange-CrossTenant-AuthAs: Anonymous X-MS-Exchange-CrossTenant-FromEntityHeader: HybridOnPrem X-MS-Exchange-Transport-CrossTenantHeadersStamped: VI1PR10MB2672 Precedence: bulk List-ID: X-Mailing-List: linux-leds@vger.kernel.org On Apollo Lake the pinctrl drivers will now come up without ACPI. Use that instead of open coding it. Create a new driver for that which can later be filled with more GPIO based models, and which has different dependencies. Signed-off-by: Henning Schild --- drivers/leds/simple/Kconfig | 12 ++- drivers/leds/simple/Makefile | 3 +- drivers/leds/simple/simatic-ipc-leds-gpio.c | 108 ++++++++++++++++++++ drivers/leds/simple/simatic-ipc-leds.c | 75 +------------- drivers/platform/x86/simatic-ipc.c | 5 +- 5 files changed, 129 insertions(+), 74 deletions(-) create mode 100644 drivers/leds/simple/simatic-ipc-leds-gpio.c diff --git a/drivers/leds/simple/Kconfig b/drivers/leds/simple/Kconfig index 9293e6b36c75..9d2487908743 100644 --- a/drivers/leds/simple/Kconfig +++ b/drivers/leds/simple/Kconfig @@ -3,10 +3,20 @@ config LEDS_SIEMENS_SIMATIC_IPC tristate "LED driver for Siemens Simatic IPCs" depends on LEDS_CLASS depends on SIEMENS_SIMATIC_IPC - select P2SB if X86 help This option enables support for the LEDs of several Industrial PCs from Siemens. To compile this driver as a module, choose M here: the module will be called simatic-ipc-leds. + +config LEDS_SIEMENS_SIMATIC_IPC_GPIO + tristate "LED driver for Siemens Simatic IPCs, GPIO based" + depends on SIEMENS_SIMATIC_IPC + depends on LEDS_GPIO + help + This option enables support for the LEDs of several Industrial PCs + from Siemens. + + To compile this driver as a module, choose M here: the module + will be called simatic-ipc-leds-gpio. diff --git a/drivers/leds/simple/Makefile b/drivers/leds/simple/Makefile index 8481f1e9e360..e1df74fb5915 100644 --- a/drivers/leds/simple/Makefile +++ b/drivers/leds/simple/Makefile @@ -1,2 +1,3 @@ # SPDX-License-Identifier: GPL-2.0 -obj-$(CONFIG_LEDS_SIEMENS_SIMATIC_IPC) += simatic-ipc-leds.o +obj-$(CONFIG_LEDS_SIEMENS_SIMATIC_IPC) += simatic-ipc-leds.o +obj-$(CONFIG_LEDS_SIEMENS_SIMATIC_IPC_GPIO) += simatic-ipc-leds-gpio.o diff --git a/drivers/leds/simple/simatic-ipc-leds-gpio.c b/drivers/leds/simple/simatic-ipc-leds-gpio.c new file mode 100644 index 000000000000..552b65a72e04 --- /dev/null +++ b/drivers/leds/simple/simatic-ipc-leds-gpio.c @@ -0,0 +1,108 @@ +// SPDX-License-Identifier: GPL-2.0 +/* + * Siemens SIMATIC IPC driver for GPIO based LEDs + * + * Copyright (c) Siemens AG, 2022 + * + * Authors: + * Henning Schild + */ + +#include +#include +#include +#include +#include + +static struct gpiod_lookup_table simatic_ipc_led_gpio_table = { + .dev_id = "leds-gpio", + .table = { + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 51, NULL, 0, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 52, NULL, 1, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 53, NULL, 2, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 57, NULL, 3, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 58, NULL, 4, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 60, NULL, 5, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 56, NULL, 6, GPIO_ACTIVE_LOW), + GPIO_LOOKUP_IDX("apollolake-pinctrl.0", 59, NULL, 7, GPIO_ACTIVE_HIGH), + } +}; + +static const struct gpio_led simatic_ipc_gpio_leds[] = { + { .name = "green:" LED_FUNCTION_STATUS "-3" }, + { .name = "red:" LED_FUNCTION_STATUS "-1" }, + { .name = "green:" LED_FUNCTION_STATUS "-1" }, + { .name = "red:" LED_FUNCTION_STATUS "-2" }, + { .name = "green:" LED_FUNCTION_STATUS "-2" }, + { .name = "red:" LED_FUNCTION_STATUS "-3" }, +}; + +static const struct gpio_led_platform_data simatic_ipc_gpio_leds_pdata = { + .num_leds = ARRAY_SIZE(simatic_ipc_gpio_leds), + .leds = simatic_ipc_gpio_leds, +}; + +static struct platform_device *simatic_leds_pdev; + +static int simatic_ipc_leds_gpio_remove(struct platform_device *pdev) +{ + gpiod_remove_lookup_table(&simatic_ipc_led_gpio_table); + platform_device_unregister(simatic_leds_pdev); + + return 0; +} + +static int simatic_ipc_leds_gpio_probe(struct platform_device *pdev) +{ + struct gpio_desc *gpiod; + int err; + + gpiod_add_lookup_table(&simatic_ipc_led_gpio_table); + simatic_leds_pdev = platform_device_register_resndata(NULL, + "leds-gpio", PLATFORM_DEVID_NONE, NULL, 0, + &simatic_ipc_gpio_leds_pdata, + sizeof(simatic_ipc_gpio_leds_pdata)); + if (IS_ERR(simatic_leds_pdev)) { + err = PTR_ERR(simatic_leds_pdev); + goto out; + } + + /* PM_BIOS_BOOT_N */ + gpiod = gpiod_get_index(&simatic_leds_pdev->dev, NULL, 6, 0); + if (IS_ERR(gpiod)) { + err = PTR_ERR(gpiod); + goto out; + } + gpiod_set_value(gpiod, 0); + gpiod_put(gpiod); + + /* PM_WDT_OUT */ + gpiod = gpiod_get_index(&simatic_leds_pdev->dev, NULL, 7, 0); + if (IS_ERR(gpiod)) { + err = PTR_ERR(gpiod); + goto out; + } + gpiod_set_value(gpiod, 0); + gpiod_put(gpiod); + + return 0; +out: + simatic_ipc_leds_gpio_remove(pdev); + + return err; +} + +static struct platform_driver simatic_ipc_led_gpio_driver = { + .probe = simatic_ipc_leds_gpio_probe, + .remove = simatic_ipc_leds_gpio_remove, + .driver = { + .name = KBUILD_MODNAME, + } +}; + +module_platform_driver(simatic_ipc_led_gpio_driver); + +MODULE_LICENSE("GPL v2"); +MODULE_ALIAS("platform:" KBUILD_MODNAME); +MODULE_SOFTDEP("pre: platform:leds-gpio"); +MODULE_AUTHOR("Henning Schild "); diff --git a/drivers/leds/simple/simatic-ipc-leds.c b/drivers/leds/simple/simatic-ipc-leds.c index 215ef5b74236..0f0dee053aa1 100644 --- a/drivers/leds/simple/simatic-ipc-leds.c +++ b/drivers/leds/simple/simatic-ipc-leds.c @@ -24,7 +24,7 @@ #define SIMATIC_IPC_LED_PORT_BASE 0x404E struct simatic_ipc_led { - unsigned int value; /* mask for io and offset for mem */ + unsigned int value; /* mask for io */ char *name; struct led_classdev cdev; }; @@ -39,21 +39,6 @@ static struct simatic_ipc_led simatic_ipc_leds_io[] = { { } }; -/* the actual start will be discovered with p2sb, 0 is a placeholder */ -struct resource simatic_ipc_led_mem_res = DEFINE_RES_MEM_NAMED(0, 0, KBUILD_MODNAME); - -static void *simatic_ipc_led_memory; - -static struct simatic_ipc_led simatic_ipc_leds_mem[] = { - {0x500 + 0x1A0, "red:" LED_FUNCTION_STATUS "-1"}, - {0x500 + 0x1A8, "green:" LED_FUNCTION_STATUS "-1"}, - {0x500 + 0x1C8, "red:" LED_FUNCTION_STATUS "-2"}, - {0x500 + 0x1D0, "green:" LED_FUNCTION_STATUS "-2"}, - {0x500 + 0x1E0, "red:" LED_FUNCTION_STATUS "-3"}, - {0x500 + 0x198, "green:" LED_FUNCTION_STATUS "-3"}, - { } -}; - static struct resource simatic_ipc_led_io_res = DEFINE_RES_IO_NAMED(SIMATIC_IPC_LED_PORT_BASE, SZ_2, KBUILD_MODNAME); @@ -89,27 +74,6 @@ static enum led_brightness simatic_ipc_led_get_io(struct led_classdev *led_cd) return inw(SIMATIC_IPC_LED_PORT_BASE) & led->value ? LED_OFF : led_cd->max_brightness; } -static void simatic_ipc_led_set_mem(struct led_classdev *led_cd, - enum led_brightness brightness) -{ - struct simatic_ipc_led *led = cdev_to_led(led_cd); - - u32 *p; - - p = simatic_ipc_led_memory + led->value; - *p = (*p & ~1) | (brightness == LED_OFF); -} - -static enum led_brightness simatic_ipc_led_get_mem(struct led_classdev *led_cd) -{ - struct simatic_ipc_led *led = cdev_to_led(led_cd); - - u32 *p; - - p = simatic_ipc_led_memory + led->value; - return (*p & 1) ? LED_OFF : led_cd->max_brightness; -} - static int simatic_ipc_leds_probe(struct platform_device *pdev) { const struct simatic_ipc_platform *plat = pdev->dev.platform_data; @@ -117,8 +81,7 @@ static int simatic_ipc_leds_probe(struct platform_device *pdev) struct simatic_ipc_led *ipcled; struct led_classdev *cdev; struct resource *res; - int err, type; - u32 *p; + int err; switch (plat->devmode) { case SIMATIC_IPC_DEVICE_227D: @@ -133,35 +96,10 @@ static int simatic_ipc_leds_probe(struct platform_device *pdev) } ipcled = simatic_ipc_leds_io; } - type = IORESOURCE_IO; if (!devm_request_region(dev, res->start, resource_size(res), KBUILD_MODNAME)) { dev_err(dev, "Unable to register IO resource at %pR\n", res); return -EBUSY; } - break; - case SIMATIC_IPC_DEVICE_127E: - res = &simatic_ipc_led_mem_res; - ipcled = simatic_ipc_leds_mem; - type = IORESOURCE_MEM; - - err = p2sb_bar(NULL, 0, res); - if (err) - return err; - - /* do the final address calculation */ - res->start = res->start + (0xC5 << 16); - res->end = res->start + SZ_4K - 1; - - simatic_ipc_led_memory = devm_ioremap_resource(dev, res); - if (IS_ERR(simatic_ipc_led_memory)) - return PTR_ERR(simatic_ipc_led_memory); - - /* initialize power/watchdog LED */ - p = simatic_ipc_led_memory + 0x500 + 0x1D8; /* PM_WDT_OUT */ - *p = (*p & ~1); - p = simatic_ipc_led_memory + 0x500 + 0x1C0; /* PM_BIOS_BOOT_N */ - *p = (*p | 1); - break; default: return -ENODEV; @@ -169,13 +107,8 @@ static int simatic_ipc_leds_probe(struct platform_device *pdev) while (ipcled->value) { cdev = &ipcled->cdev; - if (type == IORESOURCE_MEM) { - cdev->brightness_set = simatic_ipc_led_set_mem; - cdev->brightness_get = simatic_ipc_led_get_mem; - } else { - cdev->brightness_set = simatic_ipc_led_set_io; - cdev->brightness_get = simatic_ipc_led_get_io; - } + cdev->brightness_set = simatic_ipc_led_set_io; + cdev->brightness_get = simatic_ipc_led_get_io; cdev->max_brightness = LED_ON; cdev->name = ipcled->name; diff --git a/drivers/platform/x86/simatic-ipc.c b/drivers/platform/x86/simatic-ipc.c index 26c35e1660cb..ca3647b751d5 100644 --- a/drivers/platform/x86/simatic-ipc.c +++ b/drivers/platform/x86/simatic-ipc.c @@ -51,6 +51,7 @@ static int register_platform_devices(u32 station_id) { u8 ledmode = SIMATIC_IPC_DEVICE_NONE; u8 wdtmode = SIMATIC_IPC_DEVICE_NONE; + char *pdevname = KBUILD_MODNAME "_leds"; int i; platform_data.devmode = SIMATIC_IPC_DEVICE_NONE; @@ -64,10 +65,12 @@ static int register_platform_devices(u32 station_id) } if (ledmode != SIMATIC_IPC_DEVICE_NONE) { + if (ledmode == SIMATIC_IPC_DEVICE_127E) + pdevname = KBUILD_MODNAME "_leds_gpio"; platform_data.devmode = ledmode; ipc_led_platform_device = platform_device_register_data(NULL, - KBUILD_MODNAME "_leds", PLATFORM_DEVID_NONE, + pdevname, PLATFORM_DEVID_NONE, &platform_data, sizeof(struct simatic_ipc_platform)); if (IS_ERR(ipc_led_platform_device))