From patchwork Mon Dec 13 12:05:01 2021 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: Henning Schild X-Patchwork-Id: 523834 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on aws-us-west-2-korg-lkml-1.web.codeaurora.org Received: from vger.kernel.org (vger.kernel.org [23.128.96.18]) by smtp.lore.kernel.org (Postfix) with ESMTP id B5994C4167D for ; Mon, 13 Dec 2021 12:05:35 +0000 (UTC) Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S236510AbhLMMFc (ORCPT ); Mon, 13 Dec 2021 07:05:32 -0500 Received: from mail-eopbgr60063.outbound.protection.outlook.com ([40.107.6.63]:64578 "EHLO EUR04-DB3-obe.outbound.protection.outlook.com" rhost-flags-OK-OK-OK-FAIL) by vger.kernel.org with ESMTP id S232762AbhLMMFR (ORCPT ); Mon, 13 Dec 2021 07:05:17 -0500 ARC-Seal: i=1; a=rsa-sha256; s=arcselector9901; d=microsoft.com; cv=none; b=JdHp08Tl/OUUPgPYnga9rnP2Ab1jOUDa6o0L9kKFBvFfVXm/iH/wZ4Uqwxe0No5B5Cw4Lo9RiCkbRIc9Rb1tBKiijxAf5DAHlahBTZC0bJ0kQz7mpmwx2jeK8mlUnvaN7PxaqJs4TfV90I1BMq/odSwbYSoYgpvw4Rm48HBzOr8oDc/liPVuTCi0edoahtznuCd4AB3keciyRGGo7uEt9kworgClKjL8LR1wf12DO19Nek1oiIzAFoI4wwqYmmupUlhwA2Hc/9fzkUuCh+4Ok8oZRJWzT0F8xcZ372VuSnvOMtedYvLjCb9pE1DcE3ZlAkDZXhaM7umOURuEOVkMWw== ARC-Message-Signature: i=1; a=rsa-sha256; c=relaxed/relaxed; d=microsoft.com; s=arcselector9901; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-AntiSpam-MessageData-ChunkCount:X-MS-Exchange-AntiSpam-MessageData-0:X-MS-Exchange-AntiSpam-MessageData-1; bh=bpQ6fvDz9lVe6PiNcyGz6TuiPeWGlMMdUgY2zDKz72w=; b=ZOK14X5s5fvHcmqdlmx1tBhq2bl5CIf29AunYmNyDS61Kjug5Guw16Iu/zXSj2uU0YYnPgmBAlEnyrcwbWsSmNrqEMb8XOHi9GRkbgb4f4KfD9FcyqXzMQfm9ONU9e5FzqohiuMuqI4PcQAjSq/6cuz8eE2U1CtZnAOw9QpAs+CZVOsCv9LFd1MJ7qy+MOBuRasvekYD8AYPkO8S+lVEyCn6w3WAHd9Oi4rDNfAkMVm1SMDLXaekWqb8zm0gfCsJyJomRO7u0r2SyKHdQxrayzLVMGu7tupkEK3k+pKwmsiSKtcCjjcInLHG1J/8DqBTL6HHtjEb72DAdQzpkyzL2A== ARC-Authentication-Results: i=1; mx.microsoft.com 1; spf=pass (sender ip is 194.138.21.73) smtp.rcpttodomain=vger.kernel.org smtp.mailfrom=siemens.com; dmarc=pass (p=none sp=none pct=100) action=none header.from=siemens.com; dkim=none (message not signed); arc=none DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=siemens.com; s=selector2; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=bpQ6fvDz9lVe6PiNcyGz6TuiPeWGlMMdUgY2zDKz72w=; b=xqmcSppORVXO+qaJPryses24jIyyZyIjoOjO5JA1rd7Zjr+5Z69jVCkSIUH4TUPC0DxsefA9qZJckMH2FOXgpsfdE7GxoOSCGvN2u7d2rWqW22jn+Q3bzpKzLBzc9+jyGyTtR8E5tdZU9cfJqhVrDzH0I6eC2NzziVQjx5J5wt+gnAPMNzNEquAiDU97Fas2qTlF2bE/+xZ+kSrbKrVMHnpnlgQd2RcajhTdsFk+SEa8V9Yfp86F2HHPdAYdXvqSxpTx+ap9k077vFdzCaMShS5wdwQdWgCVprRZVd8sxov1u5r/5F/egHBr8jli/mu4nvsuVMRf9MR5KloFpWEShw== Received: from OL1P279CA0038.NORP279.PROD.OUTLOOK.COM (2603:10a6:e10:14::7) by VI1PR10MB1552.EURPRD10.PROD.OUTLOOK.COM (2603:10a6:802:31::17) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.4755.21; Mon, 13 Dec 2021 12:05:14 +0000 Received: from HE1EUR01FT018.eop-EUR01.prod.protection.outlook.com (2603:10a6:e10:14:cafe::7a) by OL1P279CA0038.outlook.office365.com (2603:10a6:e10:14::7) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384) id 15.20.4778.17 via Frontend Transport; Mon, 13 Dec 2021 12:05:14 +0000 X-MS-Exchange-Authentication-Results: spf=pass (sender IP is 194.138.21.73) smtp.mailfrom=siemens.com; dkim=none (message not signed) header.d=none;dmarc=pass action=none header.from=siemens.com; Received-SPF: Pass (protection.outlook.com: domain of siemens.com designates 194.138.21.73 as permitted sender) receiver=protection.outlook.com; client-ip=194.138.21.73; helo=hybrid.siemens.com; Received: from hybrid.siemens.com (194.138.21.73) by HE1EUR01FT018.mail.protection.outlook.com (10.152.0.175) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256) id 15.20.4778.12 via Frontend Transport; Mon, 13 Dec 2021 12:05:14 +0000 Received: from DEMCHDC8A0A.ad011.siemens.net (139.25.226.106) by DEMCHDC9SNA.ad011.siemens.net (194.138.21.73) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256) id 15.1.2375.17; Mon, 13 Dec 2021 13:05:13 +0100 Received: from md1za8fc.ad001.siemens.net (139.25.69.80) by DEMCHDC8A0A.ad011.siemens.net (139.25.226.106) with Microsoft SMTP Server (version=TLS1_2, cipher=TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256) id 15.1.2375.17; Mon, 13 Dec 2021 13:05:13 +0100 From: Henning Schild To: , , , CC: Srikanth Krishnakar , Jan Kiszka , Henning Schild , "Gerd Haeussler" , Guenter Roeck , Wim Van Sebroeck , Mark Gross , Hans de Goede , Pavel Machek , Andy Shevchenko , Enrico Weigelt Subject: [PATCH v5 3/4] watchdog: simatic-ipc-wdt: add new driver for Siemens Industrial PCs Date: Mon, 13 Dec 2021 13:05:01 +0100 Message-ID: <20211213120502.20661-4-henning.schild@siemens.com> X-Mailer: git-send-email 2.32.0 In-Reply-To: <20211213120502.20661-1-henning.schild@siemens.com> References: <20211213120502.20661-1-henning.schild@siemens.com> MIME-Version: 1.0 X-Originating-IP: [139.25.69.80] X-ClientProxiedBy: DEMCHDC89YA.ad011.siemens.net (139.25.226.104) To DEMCHDC8A0A.ad011.siemens.net (139.25.226.106) X-EOPAttributedMessage: 0 X-MS-PublicTrafficType: Email X-MS-Office365-Filtering-Correlation-Id: 2eb814d9-7688-43d1-dbfb-08d9be30d220 X-MS-TrafficTypeDiagnostic: VI1PR10MB1552:EE_ X-Microsoft-Antispam-PRVS: X-MS-Oob-TLC-OOBClassifiers: OLM:1417; X-MS-Exchange-SenderADCheck: 1 X-MS-Exchange-AntiSpam-Relay: 0 X-Microsoft-Antispam: BCL:0; X-Microsoft-Antispam-Message-Info: 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 X-Forefront-Antispam-Report: CIP:194.138.21.73; CTRY:DE; LANG:en; SCL:1; SRV:; IPV:NLI; SFV:NSPM; H:hybrid.siemens.com; PTR:InfoDomainNonexistent; CAT:NONE; SFS:(4636009)(46966006)(36840700001)(81166007)(186003)(16526019)(8936002)(4326008)(8676002)(26005)(956004)(44832011)(316002)(5660300002)(82310400004)(82960400001)(47076005)(2616005)(2906002)(70586007)(356005)(336012)(508600001)(70206006)(7416002)(83380400001)(86362001)(1076003)(6666004)(110136005)(54906003)(36756003)(36860700001)(36900700001); DIR:OUT; SFP:1101; X-OriginatorOrg: siemens.com X-MS-Exchange-CrossTenant-OriginalArrivalTime: 13 Dec 2021 12:05:14.1931 (UTC) X-MS-Exchange-CrossTenant-Network-Message-Id: 2eb814d9-7688-43d1-dbfb-08d9be30d220 X-MS-Exchange-CrossTenant-Id: 38ae3bcd-9579-4fd4-adda-b42e1495d55a X-MS-Exchange-CrossTenant-OriginalAttributedTenantConnectingIp: TenantId=38ae3bcd-9579-4fd4-adda-b42e1495d55a; Ip=[194.138.21.73]; Helo=[hybrid.siemens.com] X-MS-Exchange-CrossTenant-AuthSource: HE1EUR01FT018.eop-EUR01.prod.protection.outlook.com X-MS-Exchange-CrossTenant-AuthAs: Anonymous X-MS-Exchange-CrossTenant-FromEntityHeader: HybridOnPrem X-MS-Exchange-Transport-CrossTenantHeadersStamped: VI1PR10MB1552 Precedence: bulk List-ID: X-Mailing-List: linux-leds@vger.kernel.org This driver adds initial support for several devices from Siemens. It is based on a platform driver introduced in an earlier commit. One of the supported machines does access a GPIO pin to enable the watchdog. Here we poke GPIO memory because pinctrl does not come up. Signed-off-by: Henning Schild Reviewed-by: Guenter Roeck --- drivers/watchdog/Kconfig | 11 ++ drivers/watchdog/Makefile | 1 + drivers/watchdog/simatic-ipc-wdt.c | 228 +++++++++++++++++++++++++++++ 3 files changed, 240 insertions(+) create mode 100644 drivers/watchdog/simatic-ipc-wdt.c diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig index 9d222ba17ec6..1dc86eb1361a 100644 --- a/drivers/watchdog/Kconfig +++ b/drivers/watchdog/Kconfig @@ -1589,6 +1589,17 @@ config NIC7018_WDT To compile this driver as a module, choose M here: the module will be called nic7018_wdt. +config SIEMENS_SIMATIC_IPC_WDT + tristate "Siemens Simatic IPC Watchdog" + depends on SIEMENS_SIMATIC_IPC + select WATCHDOG_CORE + help + This driver adds support for several watchdogs found in Industrial + PCs from Siemens. + + To compile this driver as a module, choose M here: the module will be + called simatic-ipc-wdt. + # M68K Architecture config M54xx_WATCHDOG diff --git a/drivers/watchdog/Makefile b/drivers/watchdog/Makefile index 2ee97064145b..31b931846e32 100644 --- a/drivers/watchdog/Makefile +++ b/drivers/watchdog/Makefile @@ -143,6 +143,7 @@ obj-$(CONFIG_NI903X_WDT) += ni903x_wdt.o obj-$(CONFIG_NIC7018_WDT) += nic7018_wdt.o obj-$(CONFIG_MLX_WDT) += mlx_wdt.o obj-$(CONFIG_KEEMBAY_WATCHDOG) += keembay_wdt.o +obj-$(CONFIG_SIEMENS_SIMATIC_IPC_WDT) += simatic-ipc-wdt.o # M68K Architecture obj-$(CONFIG_M54xx_WATCHDOG) += m54xx_wdt.o diff --git a/drivers/watchdog/simatic-ipc-wdt.c b/drivers/watchdog/simatic-ipc-wdt.c new file mode 100644 index 000000000000..8bac793c63fb --- /dev/null +++ b/drivers/watchdog/simatic-ipc-wdt.c @@ -0,0 +1,228 @@ +// SPDX-License-Identifier: GPL-2.0 +/* + * Siemens SIMATIC IPC driver for Watchdogs + * + * Copyright (c) Siemens AG, 2020-2021 + * + * Authors: + * Gerd Haeussler + */ + +#include +#include +#include +#include +#include +#include +#include +#include +#include +#include +#include +#include +#include + +#define WD_ENABLE_IOADR 0x62 +#define WD_TRIGGER_IOADR 0x66 +#define GPIO_COMMUNITY0_PORT_ID 0xaf +#define PAD_CFG_DW0_GPP_A_23 0x4b8 +#define SAFE_EN_N_427E 0x01 +#define SAFE_EN_N_227E 0x04 +#define WD_ENABLED 0x01 +#define WD_TRIGGERED 0x80 +#define WD_MACROMODE 0x02 + +#define TIMEOUT_MIN 2 +#define TIMEOUT_DEF 64 +#define TIMEOUT_MAX 64 + +#define GP_STATUS_REG_227E 0x404D /* IO PORT for SAFE_EN_N on 227E */ + +static bool nowayout = WATCHDOG_NOWAYOUT; +module_param(nowayout, bool, 0000); +MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default=" + __MODULE_STRING(WATCHDOG_NOWAYOUT) ")"); + +static struct resource gp_status_reg_227e_res = + DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1, KBUILD_MODNAME); + +static struct resource io_resource_enable = + DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1, + KBUILD_MODNAME " WD_ENABLE_IOADR"); + +static struct resource io_resource_trigger = + DEFINE_RES_IO_NAMED(WD_TRIGGER_IOADR, SZ_1, + KBUILD_MODNAME " WD_TRIGGER_IOADR"); + +/* the actual start will be discovered with pci, 0 is a placeholder */ +static struct resource mem_resource = + DEFINE_RES_MEM_NAMED(0, SZ_4, "WD_RESET_BASE_ADR"); + +static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 }; +static void __iomem *wd_reset_base_addr; + +static int wd_start(struct watchdog_device *wdd) +{ + outb(inb(WD_ENABLE_IOADR) | WD_ENABLED, WD_ENABLE_IOADR); + return 0; +} + +static int wd_stop(struct watchdog_device *wdd) +{ + outb(inb(WD_ENABLE_IOADR) & ~WD_ENABLED, WD_ENABLE_IOADR); + return 0; +} + +static int wd_ping(struct watchdog_device *wdd) +{ + inb(WD_TRIGGER_IOADR); + return 0; +} + +static int wd_set_timeout(struct watchdog_device *wdd, unsigned int t) +{ + int timeout_idx = find_closest(t, wd_timeout_table, + ARRAY_SIZE(wd_timeout_table)); + + outb((inb(WD_ENABLE_IOADR) & 0xc7) | timeout_idx << 3, WD_ENABLE_IOADR); + wdd->timeout = wd_timeout_table[timeout_idx]; + return 0; +} + +static const struct watchdog_info wdt_ident = { + .options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING | + WDIOF_SETTIMEOUT, + .identity = KBUILD_MODNAME, +}; + +static const struct watchdog_ops wdt_ops = { + .owner = THIS_MODULE, + .start = wd_start, + .stop = wd_stop, + .ping = wd_ping, + .set_timeout = wd_set_timeout, +}; + +static void wd_secondary_enable(u32 wdtmode) +{ + u16 resetbit; + + /* set safe_en_n so we are not just WDIOF_ALARMONLY */ + if (wdtmode == SIMATIC_IPC_DEVICE_227E) { + /* enable SAFE_EN_N on GP_STATUS_REG_227E */ + resetbit = inb(GP_STATUS_REG_227E); + outb(resetbit & ~SAFE_EN_N_227E, GP_STATUS_REG_227E); + } else { + /* enable SAFE_EN_N on PCH D1600 */ + resetbit = ioread16(wd_reset_base_addr); + iowrite16(resetbit & ~SAFE_EN_N_427E, wd_reset_base_addr); + } +} + +static int wd_setup(u32 wdtmode) +{ + unsigned int bootstatus = 0; + int timeout_idx; + + timeout_idx = find_closest(TIMEOUT_DEF, wd_timeout_table, + ARRAY_SIZE(wd_timeout_table)); + + if (inb(WD_ENABLE_IOADR) & WD_TRIGGERED) + bootstatus |= WDIOF_CARDRESET; + + /* reset alarm bit, set macro mode, and set timeout */ + outb(WD_TRIGGERED | WD_MACROMODE | timeout_idx << 3, WD_ENABLE_IOADR); + + wd_secondary_enable(wdtmode); + + return bootstatus; +} + +static struct watchdog_device wdd_data = { + .info = &wdt_ident, + .ops = &wdt_ops, + .min_timeout = TIMEOUT_MIN, + .max_timeout = TIMEOUT_MAX +}; + +static int simatic_ipc_wdt_probe(struct platform_device *pdev) +{ + struct simatic_ipc_platform *plat = pdev->dev.platform_data; + struct device *dev = &pdev->dev; + struct resource *res; + + switch (plat->devmode) { + case SIMATIC_IPC_DEVICE_227E: + if (!devm_request_region(dev, gp_status_reg_227e_res.start, + resource_size(&gp_status_reg_227e_res), + KBUILD_MODNAME)) { + dev_err(dev, + "Unable to register IO resource at %pR\n", + &gp_status_reg_227e_res); + return -EBUSY; + } + fallthrough; + case SIMATIC_IPC_DEVICE_427E: + wdd_data.parent = dev; + break; + default: + return -EINVAL; + } + + if (!devm_request_region(dev, io_resource_enable.start, + resource_size(&io_resource_enable), + io_resource_enable.name)) { + dev_err(dev, + "Unable to register IO resource at %#x\n", + WD_ENABLE_IOADR); + return -EBUSY; + } + + if (!devm_request_region(dev, io_resource_trigger.start, + resource_size(&io_resource_trigger), + io_resource_trigger.name)) { + dev_err(dev, + "Unable to register IO resource at %#x\n", + WD_TRIGGER_IOADR); + return -EBUSY; + } + + if (plat->devmode == SIMATIC_IPC_DEVICE_427E) { + res = &mem_resource; + + /* get GPIO base from PCI */ + res->start = simatic_ipc_get_membase0(PCI_DEVFN(0x1f, 1)); + if (res->start == 0) + return -ENODEV; + + /* do the final address calculation */ + res->start = res->start + (GPIO_COMMUNITY0_PORT_ID << 16) + + PAD_CFG_DW0_GPP_A_23; + res->end += res->start; + + wd_reset_base_addr = devm_ioremap_resource(dev, res); + if (IS_ERR(wd_reset_base_addr)) + return PTR_ERR(wd_reset_base_addr); + } + + wdd_data.bootstatus = wd_setup(plat->devmode); + if (wdd_data.bootstatus) + dev_warn(dev, "last reboot caused by watchdog reset\n"); + + watchdog_set_nowayout(&wdd_data, nowayout); + watchdog_stop_on_reboot(&wdd_data); + return devm_watchdog_register_device(dev, &wdd_data); +} + +static struct platform_driver simatic_ipc_wdt_driver = { + .probe = simatic_ipc_wdt_probe, + .driver = { + .name = KBUILD_MODNAME, + }, +}; + +module_platform_driver(simatic_ipc_wdt_driver); + +MODULE_LICENSE("GPL v2"); +MODULE_ALIAS("platform:" KBUILD_MODNAME); +MODULE_AUTHOR("Gerd Haeussler ");