@@ -36,6 +36,8 @@
#define TIM_EGR_UG BIT(0)
+#define MIN_DELTA 0x60
+
static int stm32_clock_event_shutdown(struct clock_event_device *evt)
{
struct timer_of *to = to_timer_of(evt);
@@ -129,7 +131,8 @@ static int __init stm32_clockevent_init(struct device_node *node)
writel_relaxed(0, timer_of_base(to) + TIM_SR);
clockevents_config_and_register(&to->clkevt,
- timer_of_period(to), 0x1, max_delta);
+ timer_of_period(to),
+ MIN_DELTA, max_delta);
pr_info("%pOF: STM32 clockevent driver initialized (%d bits)\n",
node, bits);
The CPU is a CortexM4 @ 200MHZ and the clocks driving the timers are at 90MHZ with a min delta at 1 you could have an interrupt each 0.01 ms which is really to much. By increase it to 0x60 it give more time (around 1 ms) to CPU to handle the interrupt. Signed-off-by: Benjamin Gaignard <benjamin.gaignard@linaro.org> --- drivers/clocksource/timer-stm32.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) -- 2.7.4 -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html