@@ -592,13 +592,19 @@ static struct clk_rcg2 gcc_qupv3_spi1_clk_src = {
};
static const struct freq_tbl ftbl_gcc_qupv3_uart0_clk_src[] = {
- F(960000, P_XO, 10, 2, 5),
- F(4800000, P_XO, 5, 0, 0),
- F(9600000, P_XO, 2, 4, 5),
- F(16000000, P_GPLL0_OUT_MAIN, 10, 1, 5),
+ F(3686400, P_GCC_GPLL0_OUT_MAIN_DIV_CLK_SRC, 1, 144, 15625),
+ F(7372800, P_GCC_GPLL0_OUT_MAIN_DIV_CLK_SRC, 1, 288, 15625),
+ F(14745600, P_GCC_GPLL0_OUT_MAIN_DIV_CLK_SRC, 1, 576, 15625),
F(24000000, P_XO, 1, 0, 0),
F(25000000, P_GPLL0_OUT_MAIN, 16, 1, 2),
- F(50000000, P_GPLL0_OUT_MAIN, 16, 0, 0),
+ F(32000000, P_GPLL0_OUT_MAIN, 1, 1, 25),
+ F(40000000, P_GPLL0_OUT_MAIN, 1, 1, 20),
+ F(46400000, P_GPLL0_OUT_MAIN, 1, 29, 500),
+ F(48000000, P_GPLL0_OUT_MAIN, 1, 3, 50),
+ F(51200000, P_GPLL0_OUT_MAIN, 1, 8, 125),
+ F(56000000, P_GPLL0_OUT_MAIN, 1, 7, 100),
+ F(58982400, P_GPLL0_OUT_MAIN, 1, 1152, 15625),
+ F(60000000, P_GPLL0_OUT_MAIN, 1, 3, 40),
F(64000000, P_GPLL0_OUT_MAIN, 12.5, 0, 0),
{ }
};
The UART’s software and hardware flow control are currently not functioning correctly. For software flow control, the following error is encountered: qcom_geni_serial 1a80000.serial: Couldn't find suitable clock rate for 56000000, 3500000, 2500000, 1152000, 921600, 19200 During hardware flow control testing, a “Retry 0: Got ZCAN error” is observed. To address these issues, update the UART frequency table to include all supported frequencies according to the frequency plan. Signed-off-by: Manikanta Mylavarapu <quic_mmanikan@quicinc.com> --- drivers/clk/qcom/gcc-ipq5424.c | 16 +++++++++++----- 1 file changed, 11 insertions(+), 5 deletions(-)