Message ID | 20231212142730.998913-4-vincent.guittot@linaro.org |
---|---|
State | Superseded |
Headers | show |
Series | Rework system pressure interface to the scheduler | expand |
On 12/12/23 14:27, Vincent Guittot wrote: > arch_update_thermal_pressure() aims to update fast changing signal which > should be averaged using PELT filtering before being provided to the > scheduler which can't make smart use of fast changing signal. > cpufreq now provides the maximum freq_qos pressure on the capacity to the > scheduler, which includes cpufreq cooling device. Remove the call to > arch_update_thermal_pressure() in cpufreq cooling device as this is > handled by cpufreq_get_pressure(). > > Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org> > --- > drivers/thermal/cpufreq_cooling.c | 3 --- > 1 file changed, 3 deletions(-) > > diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c > index e2cc7bd30862..e77d3b44903e 100644 > --- a/drivers/thermal/cpufreq_cooling.c > +++ b/drivers/thermal/cpufreq_cooling.c > @@ -448,7 +448,6 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, > unsigned long state) > { > struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > - struct cpumask *cpus; > unsigned int frequency; > int ret; > > @@ -465,8 +464,6 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, > ret = freq_qos_update_request(&cpufreq_cdev->qos_req, frequency); > if (ret >= 0) { > cpufreq_cdev->cpufreq_state = state; > - cpus = cpufreq_cdev->policy->related_cpus; > - arch_update_thermal_pressure(cpus, frequency); > ret = 0; > } > Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c index e2cc7bd30862..e77d3b44903e 100644 --- a/drivers/thermal/cpufreq_cooling.c +++ b/drivers/thermal/cpufreq_cooling.c @@ -448,7 +448,6 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, unsigned long state) { struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; - struct cpumask *cpus; unsigned int frequency; int ret; @@ -465,8 +464,6 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, ret = freq_qos_update_request(&cpufreq_cdev->qos_req, frequency); if (ret >= 0) { cpufreq_cdev->cpufreq_state = state; - cpus = cpufreq_cdev->policy->related_cpus; - arch_update_thermal_pressure(cpus, frequency); ret = 0; }
arch_update_thermal_pressure() aims to update fast changing signal which should be averaged using PELT filtering before being provided to the scheduler which can't make smart use of fast changing signal. cpufreq now provides the maximum freq_qos pressure on the capacity to the scheduler, which includes cpufreq cooling device. Remove the call to arch_update_thermal_pressure() in cpufreq cooling device as this is handled by cpufreq_get_pressure(). Signed-off-by: Vincent Guittot <vincent.guittot@linaro.org> --- drivers/thermal/cpufreq_cooling.c | 3 --- 1 file changed, 3 deletions(-)