diff mbox series

serial: imx: fix tx statemachine deadlock

Message ID AM0PR09MB26750E782F81CD447058FE7D95CBA@AM0PR09MB2675.eurprd09.prod.outlook.com
State Superseded
Headers show
Series serial: imx: fix tx statemachine deadlock | expand

Commit Message

Paul Geurts Oct. 4, 2023, 9:57 a.m. UTC
When using the serial port as RS485 port, the tx statemachine is used to
control the RTS pin to drive the RS485 transceiver TX_EN pin. When the
TTY port is closed in the middle of a transmission (for instance during
userland application crash), imx_uart_shutdown disables the interface
and disables the Transmission Complete interrupt. afer that,
imx_uart_stop_tx bails on an incomplete transmission, to be retriggered
by the TC interrupt. This interrupt is disabled and therefore the tx
statemachine never transitions out of SEND. The statemachine is in
deadlock now, and the TX_EN remains low, making the interface useless.

imx_uart_stop_tx now checks for incomplete transmission AND whether TC
interrupts are enabled before bailing to be retriggered. This makes sure
the state machine handling is reached, and is properly set to
WAIT_AFTER_SEND.

Signed-off-by: Paul Geurts <paul_geurts@live.nl>
---
 drivers/tty/serial/imx.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)
diff mbox series

Patch

diff --git a/drivers/tty/serial/imx.c b/drivers/tty/serial/imx.c
index 13cb78340709..90a4b7841030 100644
--- a/drivers/tty/serial/imx.c
+++ b/drivers/tty/serial/imx.c
@@ -421,13 +421,13 @@  static void imx_uart_stop_tx(struct uart_port *port)
 	ucr1 = imx_uart_readl(sport, UCR1);
 	imx_uart_writel(sport, ucr1 & ~UCR1_TRDYEN, UCR1);
 
+	ucr4 = imx_uart_readl(sport, UCR4);
 	usr2 = imx_uart_readl(sport, USR2);
-	if (!(usr2 & USR2_TXDC)) {
+	if ((!(usr2 & USR2_TXDC)) && (ucr4 & UCR4_TCEN)) {
 		/* The shifter is still busy, so retry once TC triggers */
 		return;
 	}
 
-	ucr4 = imx_uart_readl(sport, UCR4);
 	ucr4 &= ~UCR4_TCEN;
 	imx_uart_writel(sport, ucr4, UCR4);