@@ -67,10 +67,6 @@ static unsigned long get_target_state(struct thermal_instance *instance,
next_target = clamp((cur_state + 1), instance->lower, instance->upper);
}
break;
- case THERMAL_TREND_RAISE_FULL:
- if (throttle)
- next_target = instance->upper;
- break;
case THERMAL_TREND_DROPPING:
if (cur_state <= instance->lower) {
if (!throttle)
@@ -81,13 +77,6 @@ static unsigned long get_target_state(struct thermal_instance *instance,
}
}
break;
- case THERMAL_TREND_DROP_FULL:
- if (cur_state == instance->lower) {
- if (!throttle)
- next_target = THERMAL_NO_TARGET;
- } else
- next_target = instance->lower;
- break;
default:
break;
}
@@ -40,8 +40,6 @@ enum thermal_trend {
THERMAL_TREND_STABLE, /* temperature is stable */
THERMAL_TREND_RAISING, /* temperature is raising */
THERMAL_TREND_DROPPING, /* temperature is dropping */
- THERMAL_TREND_RAISE_FULL, /* apply highest cooling action */
- THERMAL_TREND_DROP_FULL, /* apply lowest cooling action */
};
/* Thermal notification reason */