@@ -53,6 +53,7 @@ static unsigned int fmax = 515633;
* @sdio: variant supports SDIO
* @st_clkdiv: true if using a ST-specific clock divider algorithm
* @blksz_datactrl16: true if Block size is at b16..b30 position in datactrl register
+ * @pwrreg_powerup: power up value for MMCIPOWER register
*/
struct variant_data {
unsigned int clkreg;
@@ -63,18 +64,21 @@ struct variant_data {
bool sdio;
bool st_clkdiv;
bool blksz_datactrl16;
+ u32 pwrreg_powerup;
};
static struct variant_data variant_arm = {
.fifosize = 16 * 4,
.fifohalfsize = 8 * 4,
.datalength_bits = 16,
+ .pwrreg_powerup = MCI_PWR_UP,
};
static struct variant_data variant_arm_extended_fifo = {
.fifosize = 128 * 4,
.fifohalfsize = 64 * 4,
.datalength_bits = 16,
+ .pwrreg_powerup = MCI_PWR_UP,
};
static struct variant_data variant_u300 = {
@@ -83,6 +87,7 @@ static struct variant_data variant_u300 = {
.clkreg_enable = MCI_ST_U300_HWFCEN,
.datalength_bits = 16,
.sdio = true,
+ .pwrreg_powerup = MCI_PWR_ON,
};
static struct variant_data variant_ux500 = {
@@ -93,6 +98,7 @@ static struct variant_data variant_ux500 = {
.datalength_bits = 24,
.sdio = true,
.st_clkdiv = true,
+ .pwrreg_powerup = MCI_PWR_ON,
};
static struct variant_data variant_ux500v2 = {
@@ -104,6 +110,7 @@ static struct variant_data variant_ux500v2 = {
.sdio = true,
.st_clkdiv = true,
.blksz_datactrl16 = true,
+ .pwrreg_powerup = MCI_PWR_ON,
};
/*
@@ -1002,6 +1009,7 @@ static void mmci_request(struct mmc_host *mmc, struct mmc_request *mrq)
static void mmci_set_ios(struct mmc_host *mmc, struct mmc_ios *ios)
{
struct mmci_host *host = mmc_priv(mmc);
+ struct variant_data *variant = host->variant;
u32 pwr = 0;
unsigned long flags;
int ret;
@@ -1028,11 +1036,15 @@ static void mmci_set_ios(struct mmc_host *mmc, struct mmc_ios *ios)
if (host->plat->vdd_handler)
pwr |= host->plat->vdd_handler(mmc_dev(mmc), ios->vdd,
ios->power_mode);
- /* The ST version does not have this, fall through to POWER_ON */
- if (host->hw_designer != AMBA_VENDOR_ST) {
- pwr |= MCI_PWR_UP;
- break;
- }
+
+ /*
+ * The ST Micro variant doesn't have the PL180s MCI_PWR_UP
+ * and instead uses MCI_PWR_ON so apply whatever value is
+ * configured in the variant data.
+ */
+ pwr |= variant->pwrreg_powerup;
+
+ break;
case MMC_POWER_ON:
pwr |= MCI_PWR_ON;
break;