@@ -10,6 +10,12 @@ Optional properties:
- dlg,use-sw-pm: Add this property to disable the watchdog during suspend.
Only use this option if you can't use the watchdog automatic suspend
function during a suspend (see register CONTROL_B).
+- dlg,wdt-sd: Set what happens on watchdog timeout. If this bit is set the
+ watchdog timeout triggers SHUTDOWN, if cleared the watchdog triggers
+ POWERDOWN. Can be 0 or 1. Only use this option if you want to change the
+ default chip's OTP setting for WATCHDOG_SD bit. If this property is NOT
+ set the WATCHDOG_SD bit and on timeout watchdog behavior will match the
+ chip's OTP settings.
Example: DA9062
Document the watchdog timeout mode property. If this property is used the user can select what happens on watchdog timeout. Set this property to 1 to enable SHUTDOWN (the device resets), set it to 0 and the device will go to POWERDOWN on watchdog timeout. If this property is not set, don't touch the WATCHDOG_SD bit and leave the configuration to OTP. This way backward compatibility is not broken. Signed-off-by: Andrej Picej <andrej.picej@norik.com> --- Changes in v3: - add note about using the default OTP setting if this DT binding is not specified Changes in v2: - new patch, document new DT binding --- Documentation/devicetree/bindings/watchdog/da9062-wdt.txt | 6 ++++++ 1 file changed, 6 insertions(+)