Andrej Picej Nov. 24, 2021, 8:32 a.m. UTC
From: Stefan Christ <s.christ@phytec.de>

Make the config register CONFIG_I writable to change the watchdog mode.

Signed-off-by: Stefan Christ <s.christ@phytec.de>
Signed-off-by: Andrej Picej <andrej.picej@norik.com>
---
 drivers/mfd/da9062-core.c | 1 +
 1 file changed, 1 insertion(+)

Comments

Adam Thomson Nov. 26, 2021, 1:28 p.m. UTC | #1
On 24 November 2021 08:33, Andrej Picej wrote:

> From: Stefan Christ <s.christ@phytec.de>
>
> In the default fuse configuration the watchdog poweroffs the system
> instead of resetting it on a watchdog timeout. This patch changes the
> behavior. Now the board is reseted and reboots.
>
> Note: This patch requires that the config register CONFIG_I is
> configured as writable in the da9062 multi function device.

I'm a little concerned about forcing this change in the driver. There may be
platforms which don't want the PMIC to perform a full reset through OTP re-read
and if we hard code this change then that's impacting those platforms. If we
want/need this then I think it should probably be a DT binding for da9061/2
which then indicates the behaviour we want.

NRES_MODE bit also plays a part here as it controls whether or not the nRESET
line state is changed as part of the power-down/up process. I'm assuming for
your setup this bit is 0?

>
> Signed-off-by: Stefan Christ <s.christ@phytec.de>
> Signed-off-by: Andrej Picej <andrej.picej@norik.com>
> ---
>  drivers/watchdog/da9062_wdt.c | 14 ++++++++++++++
>  1 file changed, 14 insertions(+)
>
> diff --git a/drivers/watchdog/da9062_wdt.c b/drivers/watchdog/da9062_wdt.c
> index f02cbd530538..a04613e68f4a 100644
> --- a/drivers/watchdog/da9062_wdt.c
> +++ b/drivers/watchdog/da9062_wdt.c
> @@ -87,6 +87,20 @@ static int da9062_wdt_start(struct watchdog_device *wdd)
>  	unsigned int selector;
>  	int ret;
>
> +	/*
> +	 * Use da9062's SHUTDOWN mode instead of POWERDOWN for
> watchdog reset.
> +	 * On timeout the PMIC should reset the system, not powering it
> +	 * off.
> +	 */
> +	ret = regmap_update_bits(wdt->hw->regmap,
> +				 DA9062AA_CONFIG_I,
> +				 DA9062AA_WATCHDOG_SD_MASK,
> +				 DA9062AA_WATCHDOG_SD_MASK);
> +	if (ret)
> +		dev_err(wdt->hw->dev,
> +			"failed to set wdt reset mode. Expect poweroff on
> watchdog reset: %d\n",
> +			ret);
> +
>  	selector = da9062_wdt_timeout_to_sel(wdt->wdtdev.timeout);
>  	ret = da9062_wdt_update_timeout_register(wdt, selector);
>  	if (ret)
> --
> 2.25.1
Andrej Picej Nov. 29, 2021, 12:12 p.m. UTC | #2
Hi Adam,

On 26. 11. 21 14:28, Adam Thomson wrote:
> 
> I'm a little concerned about forcing this change in the driver. There may be
> platforms which don't want the PMIC to perform a full reset through OTP re-read
> and if we hard code this change then that's impacting those platforms. If we
> want/need this then I think it should probably be a DT binding for da9061/2
> which then indicates the behaviour we want.

Ok, I see the impact this might have on the platforms that are relying 
on the current default setting. I will start on the DT binding 
implementation and submit a new patch.

> 
> NRES_MODE bit also plays a part here as it controls whether or not the nRESET
> line state is changed as part of the power-down/up process. I'm assuming for
> your setup this bit is 0?
> 
We leave NRES_MODE as it is, 0 by default I guess? So do you want a 
separate dt binding for NRES_MODE?

BR,
Andrej
diff mbox series

Patch

diff --git a/drivers/mfd/da9062-core.c b/drivers/mfd/da9062-core.c
index 01f8e10dfa55..7041ba53efb4 100644
--- a/drivers/mfd/da9062-core.c
+++ b/drivers/mfd/da9062-core.c
@@ -556,6 +556,7 @@  static const struct regmap_range da9062_aa_writeable_ranges[] = {
 	regmap_reg_range(DA9062AA_VBUCK3_B, DA9062AA_VBUCK3_B),
 	regmap_reg_range(DA9062AA_VLDO1_B, DA9062AA_VLDO4_B),
 	regmap_reg_range(DA9062AA_BBAT_CONT, DA9062AA_BBAT_CONT),
+	regmap_reg_range(DA9062AA_CONFIG_I, DA9062AA_CONFIG_I),
 	regmap_reg_range(DA9062AA_GP_ID_0, DA9062AA_GP_ID_19),
 };