diff mbox series

[net,3/3] bnxt_en: Use register window 6 instead of 5 to read the PHC

Message ID 1628362995-7938-4-git-send-email-michael.chan@broadcom.com
State New
Headers show
Series bnxt_en: PTP fixes | expand

Commit Message

Michael Chan Aug. 7, 2021, 7:03 p.m. UTC
Some older Broadcom debug tools use window 5 and may conflict, so switch
to use window 6 instead.

Fixes: 118612d519d8 ("bnxt_en: Add PTP clock APIs, ioctls, and ethtool methods")
Reviewed-by: Andy Gospodarek <gospo@broadcom.com>
Signed-off-by: Michael Chan <michael.chan@broadcom.com>
---
 drivers/net/ethernet/broadcom/bnxt/bnxt_ptp.h | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)
diff mbox series

Patch

diff --git a/drivers/net/ethernet/broadcom/bnxt/bnxt_ptp.h b/drivers/net/ethernet/broadcom/bnxt/bnxt_ptp.h
index 57a8b9243a31..524f1c272054 100644
--- a/drivers/net/ethernet/broadcom/bnxt/bnxt_ptp.h
+++ b/drivers/net/ethernet/broadcom/bnxt/bnxt_ptp.h
@@ -10,8 +10,8 @@ 
 #ifndef BNXT_PTP_H
 #define BNXT_PTP_H
 
-#define BNXT_PTP_GRC_WIN	5
-#define BNXT_PTP_GRC_WIN_BASE	0x5000
+#define BNXT_PTP_GRC_WIN	6
+#define BNXT_PTP_GRC_WIN_BASE	0x6000
 
 #define BNXT_MAX_PHC_DRIFT	31000000
 #define BNXT_LO_TIMER_MASK	0x0000ffffffffUL