@@ -2001,9 +2001,16 @@ int ieee80211_if_add(struct ieee80211_local *local, const char *name,
netdev_set_default_ethtool_ops(ndev, &ieee80211_ethtool_ops);
- /* MTU range: 256 - 2304 */
+ /* MTU range is normally 256 - 2304, where the upper limit is
+ * the maximum MSDU size. Monitor interfaces send and receive
+ * MPDU and A-MSDU frames which may be much larger so we do
+ * not impose an upper limit in that case.
+ */
ndev->min_mtu = 256;
- ndev->max_mtu = local->hw.max_mtu;
+ if (type == NL80211_IFTYPE_MONITOR)
+ ndev->max_mtu = 0;
+ else
+ ndev->max_mtu = local->hw.max_mtu;
ret = cfg80211_register_netdevice(ndev);
if (ret) {
The maximum MTU was set to 2304, which is the maximum MSDU size. While this is valid for normal WLAN interfaces, it is too low for monitor interfaces. A monitor interface may receive and inject MPDU frames, and the maximum MPDU frame size is larger than 2304. The MPDU may also contain an A-MSDU frame, in which case the size may be much larger than the MTU limit. Since the maximum size of an A-MSDU depends on the PHY mode of the transmitting STA, it is not possible to set an exact MTU limit for a monitor interface. Now the maximum MTU for a monitor interface is unrestricted. Signed-off-by: Johan Almbladh <johan.almbladh@anyfinetworks.com> --- net/mac80211/iface.c | 11 +++++++++-- 1 file changed, 9 insertions(+), 2 deletions(-)