@@ -251,7 +251,7 @@ static void realview_init(ram_addr_t ram_size,
sysbus_create_simple("pl061", 0x10014000, pic[7]);
gpio2 = sysbus_create_simple("pl061", 0x10015000, pic[8]);
- sysbus_create_simple("pl110_versatile", 0x10020000, pic[23]);
+ sysbus_create_simple("pl111", 0x10020000, pic[23]);
dev = sysbus_create_varargs("pl181", 0x10005000, pic[17], pic[18], NULL);
/* Wire up MMC card detect and read-only signals. These have
@@ -150,7 +150,7 @@ static void vexpress_a9_init(ram_addr_t ram_size,
/* Daughterboard peripherals : 0x10020000 .. 0x20000000 */
/* 0x10020000 PL111 CLCD (daughterboard) */
- sysbus_create_simple("pl110", 0x10020000, pic[44]);
+ sysbus_create_simple("pl111", 0x10020000, pic[44]);
/* 0x10060000 AXI RAM */
/* 0x100e0000 PL341 Dynamic Memory Controller */
The Versatile Express, Realview EB, PBX A9 and PB A8 boards all use a PL111 for their graphics, not a PL110. Now we model the PL111, use it on these board models. Signed-off-by: Peter Maydell <peter.maydell@linaro.org> --- hw/realview.c | 2 +- hw/vexpress.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)