@@ -20,8 +20,6 @@ Mandatory properties
dependent).
- clocks: External clock to the sensor
- clock-frequency: Frequency of the external clock to the sensor
-- link-frequencies: List of allowed data link frequencies. An array of
- 64-bit elements.
Optional properties
@@ -39,6 +37,8 @@ Endpoint node mandatory properties
----------------------------------
- data-lanes: <1..n>
+- link-frequencies: List of allowed data link frequencies. An array of
+ 64-bit elements.
Example
@@ -55,11 +55,13 @@ Example
clocks = <&omap3_isp 0>;
clock-frequency = <9600000>;
nokia,nvm-size = <512>; /* 8 * 64 */
- link-frequencies = /bits/ 64 <199200000 210000000 499200000>;
port {
smiapp_ep: endpoint {
data-lanes = <1 2>;
remote-endpoint = <&csi2a_ep>;
+ link-frequencies =
+ /bits/ 64 <199200000 210000000
+ 499200000>;
};
};
};