Message ID | 20200917032226.820371-2-thara.gopinath@linaro.org |
---|---|
State | New |
Headers | show |
Series | Introduce warming in thermal framework | expand |
On Wed, Sep 16, 2020 at 11:22:19PM -0400, Thara Gopinath wrote: > Introduce a new binding parameter to thermal trip point description > to indicate whether the temperature level specified by the trip point > is monitored for a rise or fall in temperature. > > Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org> > --- > .../devicetree/bindings/thermal/thermal-zones.yaml | 7 +++++++ > 1 file changed, 7 insertions(+) > > diff --git a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml > index 3ec9cc87ec50..cc1332ad6c16 100644 > --- a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml > +++ b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml > @@ -161,6 +161,13 @@ patternProperties: > The active trip type can be used to control other HW to > help in cooling e.g. fans can be sped up or slowed down > > + monitor-falling: > + description: | > + boolean, If true, the trip point is being monitored for > + falling temperature. If false/absent/default, the trip > + point is being monitored for rising temperature. > + type: boolean What if you wanted to monitor for both? > + > required: > - temperature > - hysteresis > -- > 2.25.1 >
diff --git a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml index 3ec9cc87ec50..cc1332ad6c16 100644 --- a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml +++ b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml @@ -161,6 +161,13 @@ patternProperties: The active trip type can be used to control other HW to help in cooling e.g. fans can be sped up or slowed down + monitor-falling: + description: | + boolean, If true, the trip point is being monitored for + falling temperature. If false/absent/default, the trip + point is being monitored for rising temperature. + type: boolean + required: - temperature - hysteresis
Introduce a new binding parameter to thermal trip point description to indicate whether the temperature level specified by the trip point is monitored for a rise or fall in temperature. Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org> --- .../devicetree/bindings/thermal/thermal-zones.yaml | 7 +++++++ 1 file changed, 7 insertions(+)