diff mbox series

[4.14,138/148] platform/x86: pmc_atom: Add Lex 2I385SW to critclk_systems DMI table

Message ID 20200401161605.470703801@linuxfoundation.org
State Superseded
Headers show
Series None | expand

Commit Message

Greg KH April 1, 2020, 4:18 p.m. UTC
From: Georg Müller <georgmueller@gmx.net>

commit 95b31e35239e5e1689e3d965d692a313c71bd8ab upstream.

The Lex 2I385SW board has two Intel I211 ethernet controllers. Without
this patch, only the first port is usable. The second port fails to
start with the following message:

    igb: probe of 0000:02:00.0 failed with error -2

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Tested-by: Georg Müller <georgmueller@gmx.net>
Signed-off-by: Georg Müller <georgmueller@gmx.net>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

---
 drivers/platform/x86/pmc_atom.c |    8 ++++++++
 1 file changed, 8 insertions(+)
diff mbox series

Patch

--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -445,6 +445,14 @@  static const struct dmi_system_id critcl
 	},
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
+		.ident = "Lex 2I385SW",
+		.matches = {
+			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
+			DMI_MATCH(DMI_PRODUCT_NAME, "2I385SW"),
+		},
+	},
+	{
+		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB3163",
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),