diff mbox series

[net] net: dsa: sja1105: the PTP_CLK extts input reacts on both edges

Message ID 20200506174813.14587-1-olteanv@gmail.com
State New
Headers show
Series [net] net: dsa: sja1105: the PTP_CLK extts input reacts on both edges | expand

Commit Message

Vladimir Oltean May 6, 2020, 5:48 p.m. UTC
From: Vladimir Oltean <vladimir.oltean@nxp.com>

It looks like the sja1105 external timestamping input is not as generic
as we thought. When fed a signal with 50% duty cycle, it will timestamp
both the rising and the falling edge. When fed a short pulse signal,
only the timestamp of the falling edge will be seen in the PTPSYNCTS
register, because that of the rising edge had been overwritten. So the
moral is: don't feed it short pulse inputs.

Luckily this is not a complete deal breaker, as we can still work with
1 Hz square waves. But the problem is that the extts polling period was
not dimensioned enough for this input signal. If we leave the period at
half a second, we risk losing timestamps due to jitter in the measuring
process. So we need to increase it to 4 times per second.

Also, the very least we can do to inform the user is to deny any other
flags combination than with PTP_RISING_EDGE and PTP_FALLING_EDGE both
set.

Fixes: 747e5eb31d59 ("net: dsa: sja1105: configure the PTP_CLK pin as EXT_TS or PER_OUT")
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
---
 drivers/net/dsa/sja1105/sja1105_ptp.c | 26 ++++++++++++++++++--------
 1 file changed, 18 insertions(+), 8 deletions(-)
diff mbox series

Patch

diff --git a/drivers/net/dsa/sja1105/sja1105_ptp.c b/drivers/net/dsa/sja1105/sja1105_ptp.c
index a22f8e3fc06b..bc0e47c1dbb9 100644
--- a/drivers/net/dsa/sja1105/sja1105_ptp.c
+++ b/drivers/net/dsa/sja1105/sja1105_ptp.c
@@ -16,14 +16,15 @@ 
 
 /* PTPSYNCTS has no interrupt or update mechanism, because the intended
  * hardware use case is for the timestamp to be collected synchronously,
- * immediately after the CAS_MASTER SJA1105 switch has triggered a CASSYNC
- * pulse on the PTP_CLK pin. When used as a generic extts source, it needs
- * polling and a comparison with the old value. The polling interval is just
- * the Nyquist rate of a canonical PPS input (e.g. from a GPS module).
- * Anything of higher frequency than 1 Hz will be lost, since there is no
- * timestamp FIFO.
+ * immediately after the CAS_MASTER SJA1105 switch has performed a CASSYNC
+ * one-shot toggle (no return to level) on the PTP_CLK pin. When used as a
+ * generic extts source, the PTPSYNCTS register needs polling and a comparison
+ * with the old value. The polling interval is configured as the Nyquist rate
+ * of a signal with 50% duty cycle and 1Hz frequency, which is sadly all that
+ * this hardware can do (but may be enough for some setups). Anything of higher
+ * frequency than 1 Hz will be lost, since there is no timestamp FIFO.
  */
-#define SJA1105_EXTTS_INTERVAL		(HZ / 2)
+#define SJA1105_EXTTS_INTERVAL		(HZ / 4)
 
 /*            This range is actually +/- SJA1105_MAX_ADJ_PPB
  *            divided by 1000 (ppb -> ppm) and with a 16-bit
@@ -754,7 +755,16 @@  static int sja1105_extts_enable(struct sja1105_private *priv,
 		return -EOPNOTSUPP;
 
 	/* Reject requests with unsupported flags */
-	if (extts->flags)
+	if (extts->flags & ~(PTP_ENABLE_FEATURE |
+			     PTP_RISING_EDGE |
+			     PTP_FALLING_EDGE |
+			     PTP_STRICT_FLAGS))
+		return -EOPNOTSUPP;
+
+	/* We can only enable time stamping on both edges, sadly. */
+	if ((extts->flags & PTP_STRICT_FLAGS) &&
+	    (extts->flags & PTP_ENABLE_FEATURE) &&
+	    (extts->flags & PTP_EXTTS_EDGES) != PTP_EXTTS_EDGES)
 		return -EOPNOTSUPP;
 
 	rc = sja1105_change_ptp_clk_pin_func(priv, PTP_PF_EXTTS);