@@ -28,6 +28,12 @@ indication (including whether to use it at all) are fully controllable by
user and/or specific machine defaults, per design principles of LED
framework).
+There are three defined points of measurement for the benefit of mobile and
+UPS-like power supplies: INPUT (external power source), OUTPUT (power output
+from the module), and unmarked (power flowing to/from a storage element,
+eg. battery). Battery is viewed as a power source, so current flowing to
+the battery (charging it) is shown negative.
+
Attributes/properties
~~~~~~~~~~~~~~~~~~~~~