Datasheet describes two modes for reading ADC measurements:
1. continuous, 1 Hz - enabled and started by CONV_RATE bit
2. one-shot - triggered by CONV_START bit

In continuous mode, CONV_START is read-only and signifies an ongoing
conversion.

Change the code to follow the datasheet and really disable continuous
mode for power saving.

Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
---
 drivers/power/supply/bq25890_charger.c | 33 ++++++++++++++++++++++----
 1 file changed, 28 insertions(+), 5 deletions(-)
diff mbox series

Patch

diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c
index 9339e216651f..3b02fa80aedd 100644
--- a/drivers/power/supply/bq25890_charger.c
+++ b/drivers/power/supply/bq25890_charger.c
@@ -126,6 +126,7 @@  static const struct regmap_access_table bq25890_writeable_regs = {
 
 static const struct regmap_range bq25890_volatile_reg_ranges[] = {
 	regmap_reg_range(0x00, 0x00),
+	regmap_reg_range(0x02, 0x02),
 	regmap_reg_range(0x09, 0x09),
 	regmap_reg_range(0x0b, 0x14),
 };
@@ -374,18 +375,40 @@  enum bq25890_chrg_fault {
 	CHRG_FAULT_TIMER_EXPIRED,
 };
 
+static bool bq25890_is_adc_property(enum power_supply_property psp)
+{
+	switch (psp) {
+	case POWER_SUPPLY_PROP_INPUT_VOLTAGE_NOW:
+	case POWER_SUPPLY_PROP_OUTPUT_VOLTAGE_NOW:
+	case POWER_SUPPLY_PROP_VOLTAGE_NOW:
+	case POWER_SUPPLY_PROP_CURRENT_NOW:
+		return true;
+
+	default:
+		return false;
+	}
+}
+
 static int bq25890_power_supply_get_property(struct power_supply *psy,
 					     enum power_supply_property psp,
 					     union power_supply_propval *val)
 {
-	int ret;
 	struct bq25890_device *bq = power_supply_get_drvdata(psy);
 	struct bq25890_state state;
+	bool do_adc_conv;
+	int ret;
 
 	mutex_lock(&bq->lock);
 	state = bq->state;
+	do_adc_conv = !state.online && bq25890_is_adc_property(psp);
+	if (do_adc_conv)
+		bq25890_field_write(bq, F_CONV_START, 1);
 	mutex_unlock(&bq->lock);
 
+	if (do_adc_conv)
+		regmap_field_read_poll_timeout(bq->rmap_fields[F_CONV_START],
+			ret, !ret, 25000, 1000000);
+
 	switch (psp) {
 	case POWER_SUPPLY_PROP_STATUS:
 		if (!state.online)
@@ -623,8 +646,8 @@  static int bq25890_hw_init(struct bq25890_device *bq)
 		}
 	}
 
-	/* Configure ADC for continuous conversions. This does not enable it. */
-	ret = bq25890_field_write(bq, F_CONV_RATE, 1);
+	/* Configure ADC for continuous conversions when charging */
+	ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
 	if (ret < 0) {
 		dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
 		return ret;
@@ -966,7 +989,7 @@  static int bq25890_suspend(struct device *dev)
 	 * If charger is removed, while in suspend, make sure ADC is diabled
 	 * since it consumes slightly more power.
 	 */
-	return bq25890_field_write(bq, F_CONV_START, 0);
+	return bq25890_field_write(bq, F_CONV_RATE, 0);
 }
 
 static int bq25890_resume(struct device *dev)
@@ -982,7 +1005,7 @@  static int bq25890_resume(struct device *dev)
 
 	/* Re-enable ADC only if charger is plugged in. */
 	if (bq->state.online) {
-		ret = bq25890_field_write(bq, F_CONV_START, 1);
+		ret = bq25890_field_write(bq, F_CONV_RATE, 1);
 		if (ret < 0)
 			return ret;
 	}