new file mode 100755
@@ -0,0 +1,390 @@
+#!/bin/bash
+# SPDX-License-Identifier: GPL-2.0
+
+# This test is designed for testing the new VRF strict_mode functionality.
+
+ret=0
+
+# identifies the "init" network namespace which is often called root network
+# namespace.
+INIT_NETNS_NAME="init"
+
+PAUSE_ON_FAIL=${PAUSE_ON_FAIL:=no}
+
+log_test()
+{
+ local rc=$1
+ local expected=$2
+ local msg="$3"
+
+ if [ ${rc} -eq ${expected} ]; then
+ nsuccess=$((nsuccess+1))
+ printf "\n TEST: %-60s [ OK ]\n" "${msg}"
+ else
+ ret=1
+ nfail=$((nfail+1))
+ printf "\n TEST: %-60s [FAIL]\n" "${msg}"
+ if [ "${PAUSE_ON_FAIL}" = "yes" ]; then
+ echo
+ echo "hit enter to continue, 'q' to quit"
+ read a
+ [ "$a" = "q" ] && exit 1
+ fi
+ fi
+}
+
+print_log_test_results()
+{
+ if [ "$TESTS" != "none" ]; then
+ printf "\nTests passed: %3d\n" ${nsuccess}
+ printf "Tests failed: %3d\n" ${nfail}
+ fi
+}
+
+log_section()
+{
+ echo
+ echo "################################################################################"
+ echo "TEST SECTION: $*"
+ echo "################################################################################"
+}
+
+ip_expand_args()
+{
+ local nsname=$1
+ local nsarg=""
+
+ if [ "${nsname}" != "${INIT_NETNS_NAME}" ]; then
+ nsarg="-netns ${nsname}"
+ fi
+
+ echo "${nsarg}"
+}
+
+vrf_count()
+{
+ local nsname=$1
+ local nsarg="$(ip_expand_args ${nsname})"
+
+ ip ${nsarg} -o link show type vrf | wc -l
+}
+
+count_vrf_by_table_id()
+{
+ local nsname=$1
+ local tableid=$2
+ local nsarg="$(ip_expand_args ${nsname})"
+
+ ip ${nsarg} -d -o link show type vrf | grep "table ${tableid}" | wc -l
+}
+
+add_vrf()
+{
+ local nsname=$1
+ local vrfname=$2
+ local vrftable=$3
+ local nsarg="$(ip_expand_args ${nsname})"
+
+ ip ${nsarg} link add ${vrfname} type vrf table ${vrftable} &>/dev/null
+}
+
+add_vrf_and_check()
+{
+ local nsname=$1
+ local vrfname=$2
+ local vrftable=$3
+ local cnt
+ local rc
+
+ add_vrf ${nsname} ${vrfname} ${vrftable}; rc=$?
+
+ cnt=$(count_vrf_by_table_id ${nsname} ${vrftable})
+
+ log_test ${rc} 0 "${nsname}: add vrf ${vrfname}, ${cnt} vrfs for table ${vrftable}"
+}
+
+add_vrf_and_check_fail()
+{
+ local nsname=$1
+ local vrfname=$2
+ local vrftable=$3
+ local cnt
+ local rc
+
+ add_vrf ${nsname} ${vrfname} ${vrftable}; rc=$?
+
+ cnt=$(count_vrf_by_table_id ${nsname} ${vrftable})
+
+ log_test ${rc} 2 "${nsname}: CANNOT add vrf ${vrfname}, ${cnt} vrfs for table ${vrftable}"
+}
+
+del_vrf_and_check()
+{
+ local nsname=$1
+ local vrfname=$2
+ local nsarg="$(ip_expand_args ${nsname})"
+
+ ip ${nsarg} link del ${vrfname}
+ log_test $? 0 "${nsname}: remove vrf ${vrfname}"
+}
+
+config_vrf_and_check()
+{
+ local nsname=$1
+ local addr=$2
+ local vrfname=$3
+ local nsarg="$(ip_expand_args ${nsname})"
+
+ ip ${nsarg} link set dev ${vrfname} up && \
+ ip ${nsarg} addr add ${addr} dev ${vrfname}
+ log_test $? 0 "${nsname}: vrf ${vrfname} up, addr ${addr}"
+}
+
+read_strict_mode()
+{
+ local nsname=$1
+ local rval
+ local rc=0
+ local nsexec=""
+
+ if [ "${nsname}" != "${INIT_NETNS_NAME}" ]; then
+ # a custom network namespace is provided
+ nsexec="ip netns exec ${nsname}"
+ fi
+
+ rval="$(${nsexec} bash -c "cat /proc/sys/net/vrf/strict_mode" | \
+ grep -E "^[0-1]$")" &> /dev/null
+ if [ $? -ne 0 ]; then
+ # set errors
+ rval=255
+ rc=1
+ fi
+
+ # on success, rval can be only 0 or 1; on error, rval is equal to 255
+ echo ${rval}
+ return ${rc}
+}
+
+read_strict_mode_compare_and_check()
+{
+ local nsname=$1
+ local expected=$2
+ local res
+
+ res="$(read_strict_mode ${nsname})"
+ log_test ${res} ${expected} "${nsname}: check strict_mode=${res}"
+}
+
+set_strict_mode()
+{
+ local nsname=$1
+ local val=$2
+ local nsexec=""
+
+ if [ "${nsname}" != "${INIT_NETNS_NAME}" ]; then
+ # a custom network namespace is provided
+ nsexec="ip netns exec ${nsname}"
+ fi
+
+ ${nsexec} bash -c "echo ${val} >/proc/sys/net/vrf/strict_mode" &>/dev/null
+}
+
+enable_strict_mode()
+{
+ local nsname=$1
+
+ set_strict_mode ${nsname} 1
+}
+
+disable_strict_mode()
+{
+ local nsname=$1
+
+ set_strict_mode ${nsname} 0
+}
+
+disable_strict_mode_and_check()
+{
+ local nsname=$1
+
+ disable_strict_mode ${nsname}
+ log_test $? 0 "${nsname}: disable strict_mode (=0)"
+}
+
+enable_strict_mode_and_check()
+{
+ local nsname=$1
+
+ enable_strict_mode ${nsname}
+ log_test $? 0 "${nsname}: enable strict_mode (=1)"
+}
+
+enable_strict_mode_and_check_fail()
+{
+ local nsname=$1
+
+ enable_strict_mode ${nsname}
+ log_test $? 1 "${nsname}: CANNOT enable strict_mode"
+}
+
+strict_mode_check_default()
+{
+ local nsname=$1
+ local strictmode
+ local vrfcnt
+
+ vrfcnt=$(vrf_count ${nsname})
+ strictmode=$(read_strict_mode ${nsname})
+ log_test ${strictmode} 0 "${nsname}: strict_mode=0 by default, ${vrfcnt} vrfs"
+}
+
+setup()
+{
+ modprobe vrf
+
+ ip netns add testns
+ ip netns exec testns ip link set lo up
+}
+
+cleanup()
+{
+ ip netns del testns 2>/dev/null
+
+ ip link del vrf100 2>/dev/null
+ ip link del vrf101 2>/dev/null
+ ip link del vrf102 2>/dev/null
+
+ echo 0 >/proc/sys/net/vrf/strict_mode 2>/dev/null
+}
+
+vrf_strict_mode_tests_init()
+{
+ vrf_strict_mode_check_support init
+
+ strict_mode_check_default init
+
+ add_vrf_and_check init vrf100 100
+ config_vrf_and_check init 172.16.100.1/24 vrf100
+
+ enable_strict_mode_and_check init
+
+ add_vrf_and_check_fail init vrf101 100
+
+ disable_strict_mode_and_check init
+
+ add_vrf_and_check init vrf101 100
+ config_vrf_and_check init 172.16.101.1/24 vrf101
+
+ enable_strict_mode_and_check_fail init
+
+ del_vrf_and_check init vrf101
+
+ enable_strict_mode_and_check init
+
+ add_vrf_and_check init vrf102 102
+ config_vrf_and_check init 172.16.102.1/24 vrf102
+
+ # the strict_modle is enabled in the init
+}
+
+vrf_strict_mode_tests_testns()
+{
+ vrf_strict_mode_check_support testns
+
+ strict_mode_check_default testns
+
+ enable_strict_mode_and_check testns
+
+ add_vrf_and_check testns vrf100 100
+ config_vrf_and_check testns 10.0.100.1/24 vrf100
+
+ add_vrf_and_check_fail testns vrf101 100
+
+ add_vrf_and_check_fail testns vrf102 100
+
+ add_vrf_and_check testns vrf200 200
+
+ disable_strict_mode_and_check testns
+
+ add_vrf_and_check testns vrf101 100
+
+ add_vrf_and_check testns vrf102 100
+
+ #the strict_mode is disabled in the testns
+}
+
+vrf_strict_mode_tests_mix()
+{
+ read_strict_mode_compare_and_check init 1
+
+ read_strict_mode_compare_and_check testns 0
+
+ del_vrf_and_check testns vrf101
+
+ del_vrf_and_check testns vrf102
+
+ disable_strict_mode_and_check init
+
+ enable_strict_mode_and_check testns
+
+ enable_strict_mode_and_check init
+ enable_strict_mode_and_check init
+
+ disable_strict_mode_and_check testns
+ disable_strict_mode_and_check testns
+
+ read_strict_mode_compare_and_check init 1
+
+ read_strict_mode_compare_and_check testns 0
+}
+
+vrf_strict_mode_tests()
+{
+ log_section "VRF strict_mode test on init network namespace"
+ vrf_strict_mode_tests_init
+
+ log_section "VRF strict_mode test on testns network namespace"
+ vrf_strict_mode_tests_testns
+
+ log_section "VRF strict_mode test mixing init and testns network namespaces"
+ vrf_strict_mode_tests_mix
+}
+
+vrf_strict_mode_check_support()
+{
+ local nsname=$1
+ local output
+ local rc
+
+ output="$(lsmod | grep '^vrf' | awk '{print $1}')"
+ if [ -z "${output}" ]; then
+ modinfo vrf || return $?
+ fi
+
+ # we do not care about the value of the strict_mode; we only check if
+ # the strict_mode parameter is available or not.
+ read_strict_mode ${nsname} &>/dev/null; rc=$?
+ log_test ${rc} 0 "${nsname}: net.vrf.strict_mode is available"
+
+ return ${rc}
+}
+
+if [ "$(id -u)" -ne 0 ];then
+ echo "SKIP: Need root privileges"
+ exit 0
+fi
+
+if [ ! -x "$(command -v ip)" ]; then
+ echo "SKIP: Could not run test without ip tool"
+ exit 0
+fi
+
+cleanup &> /dev/null
+
+setup
+vrf_strict_mode_tests
+cleanup
+
+print_log_test_results
+
+exit $ret
The new strict mode functionality is tested in different configurations and on different network namespaces. Signed-off-by: Andrea Mayer <andrea.mayer@uniroma2.it> --- .../selftests/net/vrf_strict_mode_test.sh | 390 ++++++++++++++++++ 1 file changed, 390 insertions(+) create mode 100755 tools/testing/selftests/net/vrf_strict_mode_test.sh