diff mbox series

[2/3] dts: ppc: t4240rdb: add uie_unsupported property to drop warning

Message ID 20200508054925.48237-2-biwen.li@oss.nxp.com
State New
Headers show
Series [1/3] rtc: ds1374: add uie_unsupported property to drop warning | expand

Commit Message

Biwen Li (OSS) May 8, 2020, 5:49 a.m. UTC
From: Biwen Li <biwen.li@nxp.com>

This adds uie_unsupported property to drop warning as follows:
    - $ hwclock.util-linux
      hwclock.util-linux: select() to /dev/rtc0
      to wait for clock tick timed out

My case:
    - RTC ds1374's INT pin is connected to VCC on T4240RDB,
      then the RTC cannot inform cpu about the alarm interrupt

Signed-off-by: Biwen Li <biwen.li@nxp.com>
---
 arch/powerpc/boot/dts/fsl/t4240rdb.dts | 6 +++++-
 1 file changed, 5 insertions(+), 1 deletion(-)
diff mbox series

Patch

diff --git a/arch/powerpc/boot/dts/fsl/t4240rdb.dts b/arch/powerpc/boot/dts/fsl/t4240rdb.dts
index a56a705d41f7..ccdd10202e56 100644
--- a/arch/powerpc/boot/dts/fsl/t4240rdb.dts
+++ b/arch/powerpc/boot/dts/fsl/t4240rdb.dts
@@ -144,7 +144,11 @@ 
 			rtc@68 {
 				compatible = "dallas,ds1374";
 				reg = <0x68>;
-				interrupts = <0x1 0x1 0 0>;
+				// The ds1374's INT pin isn't
+				// connected to cpu's INT pin,
+				// so the rtc cannot synchronize
+				// clock tick per second.
+				uie_unsupported;
 			};
 		};