diff mbox

[4/4] clk: exynos5440: Fix incorrect placement of __initdata

Message ID 1375850921-23122-4-git-send-email-sachin.kamat@linaro.org
State Accepted
Headers show

Commit Message

Sachin Kamat Aug. 7, 2013, 4:48 a.m. UTC
__initdata should be placed between the variable name and equal
sign for the variable to be placed in the intended section.

Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
---
 drivers/clk/samsung/clk-exynos5440.c |    2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff mbox

Patch

diff --git a/drivers/clk/samsung/clk-exynos5440.c b/drivers/clk/samsung/clk-exynos5440.c
index 6d043a2..4ef38e0 100644
--- a/drivers/clk/samsung/clk-exynos5440.c
+++ b/drivers/clk/samsung/clk-exynos5440.c
@@ -97,7 +97,7 @@  static struct samsung_gate_clock exynos5440_gate_clks[] __initdata = {
 	GATE(cs250_o, "cs250_o", "cs250", CLKEN_OV_VAL, 19, 0, 0),
 };
 
-static __initdata struct of_device_id ext_clk_match[] = {
+static struct of_device_id ext_clk_match[] __initdata = {
 	{ .compatible = "samsung,clock-xtal", .data = (void *)0, },
 	{},
 };