@@ -88,41 +88,41 @@
#size-cells = <0>;
#io-channel-cells = <1>;
- ref_gnd {
+ ref_gnd@0 {
reg = <ADC5_REF_GND>;
qcom,pre-scaling = <1 1>;
};
- vref_1p25 {
+ vref_1p25@1 {
reg = <ADC5_1P25VREF>;
qcom,pre-scaling = <1 1>;
};
- pon_1: vph_pwr {
+ pon_1: vph_pwr@131 {
reg = <ADC5_VPH_PWR>;
qcom,pre-scaling = <1 3>;
};
- die_temp {
+ die_temp@6 {
reg = <ADC5_DIE_TEMP>;
qcom,pre-scaling = <1 1>;
};
- pa_therm1: thermistor1 {
+ pa_therm1: thermistor1@115 {
reg = <ADC5_AMUX_THM1_100K_PU>;
qcom,ratiometric;
qcom,hw-settle-time = <200>;
qcom,pre-scaling = <1 1>;
};
- pa_therm3: thermistor3 {
+ pa_therm3: thermistor3@117 {
reg = <ADC5_AMUX_THM3_100K_PU>;
qcom,ratiometric;
qcom,hw-settle-time = <200>;
qcom,pre-scaling = <1 1>;
};
- xo_therm: xo_temp {
+ xo_therm: xo_temp@114 {
reg = <ADC5_XO_THERM_100K_PU>;
qcom,ratiometric;
qcom,hw-settle-time = <200>;
The adc nodes have reg property but were missing the unit name, so add that to fix these warnings: arch/arm64/boot/dts/qcom/pms405.dtsi:91.12-94.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/ref_gnd: node has a reg or ranges property, but no unit name arch/arm64/boot/dts/qcom/pms405.dtsi:96.14-99.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/vref_1p25: node has a reg or ranges property, but no unit name arch/arm64/boot/dts/qcom/pms405.dtsi:101.19-104.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/vph_pwr: node has a reg or ranges property, but no unit name arch/arm64/boot/dts/qcom/pms405.dtsi:106.13-109.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/die_temp: node has a reg or ranges property, but no unit name arch/arm64/boot/dts/qcom/pms405.dtsi:111.27-116.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/thermistor1: node has a reg or ranges property, but no unit name arch/arm64/boot/dts/qcom/pms405.dtsi:118.27-123.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/thermistor3: node has a reg or ranges property, but no unit name arch/arm64/boot/dts/qcom/pms405.dtsi:125.22-130.6: Warning (unit_address_vs_reg): /soc@0/spmi@200f000/pms405@0/adc@3100/xo_temp: node has a reg or ranges property, but no unit name Signed-off-by: Vinod Koul <vkoul@kernel.org> --- arch/arm64/boot/dts/qcom/pms405.dtsi | 14 +++++++------- 1 file changed, 7 insertions(+), 7 deletions(-) -- 2.20.1