On 18/03/2025 12:19, Dmitry Baryshkov wrote: > On Tue, Mar 18, 2025 at 10:38:17AM +0000, Suzuki K Poulose wrote: >> On 17/03/2025 17:44, Dmitry Baryshkov wrote: >> >> nit: Subject: >> >> s/qcom,coresight-static-replicator/arm,coresight-static-replicator >> >>> As most other CoreSight devices the replicator can use either of the >>> optional clocks (or both). Document those optional clocks in the schema. >>> >>> Fixes: 3c15fddf3121 ("dt-bindings: arm: Convert CoreSight bindings to DT schema") >>> Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@oss.qualcomm.com> >>> --- >>> .../bindings/arm/arm,coresight-static-replicator.yaml | 10 ++++++++++ >>> 1 file changed, 10 insertions(+) >>> >>> diff --git a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml >>> index a6f793ea03b6c193fc0ff72a45e0249a63a2ba3c..56e64067ed3d63c5e293a0840858f13428bacb45 100644 >>> --- a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml >>> +++ b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml >>> @@ -30,6 +30,16 @@ properties: >>> power-domains: >>> maxItems: 1 >>> + clocks: >>> + minItems: 1 >>> + maxItems: 2 >>> + >> >> For the static replicator, you don't have an APB clock, as they can't be >> programmed. It may have an ATB clock. So minItems 0, maxItems: 1 > > It can, see qcom-apq8064.dtsi > > Also minItems:0 doesn't make sense to me. I'd rather keep this as an > optional property rather than requiring an empty set. Interesting, that must be atclk in fact. Because a static replicator only manages ATB transactions. It doesn't have an APB interface. I am not an expert in DTB schema. But the point is the clocks are optional. Suzuki > >> >> Suzuki >> >> >> >>> + clock-names: >>> + minItems: 1 >>> + enum: >>> + - apb_pclk >>> + - atclk >>> + >>> in-ports: >>> $ref: /schemas/graph.yaml#/properties/ports >>> additionalProperties: false >>> >> >
On Tue, Mar 18, 2025 at 01:37:23PM +0000, Suzuki K Poulose wrote: > On 18/03/2025 12:19, Dmitry Baryshkov wrote: > > On Tue, Mar 18, 2025 at 10:38:17AM +0000, Suzuki K Poulose wrote: > > > On 17/03/2025 17:44, Dmitry Baryshkov wrote: > > > > > > nit: Subject: > > > > > > s/qcom,coresight-static-replicator/arm,coresight-static-replicator > > > > > > > As most other CoreSight devices the replicator can use either of the > > > > optional clocks (or both). Document those optional clocks in the schema. > > > > > > > > Fixes: 3c15fddf3121 ("dt-bindings: arm: Convert CoreSight bindings to DT schema") > > > > Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@oss.qualcomm.com> > > > > --- > > > > .../bindings/arm/arm,coresight-static-replicator.yaml | 10 ++++++++++ > > > > 1 file changed, 10 insertions(+) > > > > > > > > diff --git a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml > > > > index a6f793ea03b6c193fc0ff72a45e0249a63a2ba3c..56e64067ed3d63c5e293a0840858f13428bacb45 100644 > > > > --- a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml > > > > +++ b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml > > > > @@ -30,6 +30,16 @@ properties: > > > > power-domains: > > > > maxItems: 1 > > > > + clocks: > > > > + minItems: 1 > > > > + maxItems: 2 > > > > + > > > > > > For the static replicator, you don't have an APB clock, as they can't be > > > programmed. It may have an ATB clock. So minItems 0, maxItems: 1 > > > > It can, see qcom-apq8064.dtsi > > > > Also minItems:0 doesn't make sense to me. I'd rather keep this as an > > optional property rather than requiring an empty set. > > Interesting, that must be atclk in fact. Because a static replicator > only manages ATB transactions. It doesn't have an APB interface. Ack. Unfortunately there are platforms (and grepping revealed more than just APQ8064) that list the apb_pclk. We have to support those DTs :-( > > I am not an expert in DTB schema. But the point is the clocks are optional. This is handled by not listing the 'clocks' / 'clock-names' under the 'required' list. > > Suzuki > > > > > > > > > > Suzuki > > > > > > > > > > > > > + clock-names: > > > > + minItems: 1 > > > > + enum: > > > > + - apb_pclk > > > > + - atclk > > > > + > > > > in-ports: > > > > $ref: /schemas/graph.yaml#/properties/ports > > > > additionalProperties: false > > > > > > > > > >
diff --git a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml index a6f793ea03b6c193fc0ff72a45e0249a63a2ba3c..56e64067ed3d63c5e293a0840858f13428bacb45 100644 --- a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml +++ b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml @@ -30,6 +30,16 @@ properties: power-domains: maxItems: 1 + clocks: + minItems: 1 + maxItems: 2 + + clock-names: + minItems: 1 + enum: + - apb_pclk + - atclk + in-ports: $ref: /schemas/graph.yaml#/properties/ports additionalProperties: false
As most other CoreSight devices the replicator can use either of the optional clocks (or both). Document those optional clocks in the schema. Fixes: 3c15fddf3121 ("dt-bindings: arm: Convert CoreSight bindings to DT schema") Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@oss.qualcomm.com> --- .../bindings/arm/arm,coresight-static-replicator.yaml | 10 ++++++++++ 1 file changed, 10 insertions(+)