Message ID | 20230625100251.31589-1-amit.kumar-mahapatra@amd.com |
---|---|
Headers | show |
Series | mtd: spi-nor: Avoid setting SRWD bit in SR | expand |
On Sun, Jun 25, 2023 at 03:32:50PM +0530, Amit Kumar Mahapatra wrote: > If the WP# signal of the flash device is either not connected or is wrongly > tied to GND (that includes internal pull-downs), and the software sets the > status register write disable (SRWD) bit in the status register then the > status register permanently becomes read-only. To avoid this added a new > boolean DT property "no-wp". If this property is set in the DT then the > software avoids setting the SRWD during status register write operation. > > Signed-off-by: Amit Kumar Mahapatra <amit.kumar-mahapatra@amd.com> > --- > As the DT property name has changed so, removed Reviewed-by tag. > @Cornor if possible, could you please review this updated patch. Rob was the one who objected to the property name. Old & new names are fine by me, it was the text I think I cared about. Reviewed-by: Conor Dooley <conor.dooley@microchip.com> Thanks for actually explaining why you dropped the tag, Conor. > --- > .../devicetree/bindings/mtd/jedec,spi-nor.yaml | 15 +++++++++++++++ > 1 file changed, 15 insertions(+) > > diff --git a/Documentation/devicetree/bindings/mtd/jedec,spi-nor.yaml b/Documentation/devicetree/bindings/mtd/jedec,spi-nor.yaml > index 89959e5c47ba..97344969b02d 100644 > --- a/Documentation/devicetree/bindings/mtd/jedec,spi-nor.yaml > +++ b/Documentation/devicetree/bindings/mtd/jedec,spi-nor.yaml > @@ -70,6 +70,21 @@ properties: > be used on such systems, to denote the absence of a reliable reset > mechanism. > > + no-wp: > + type: boolean > + description: > + The status register write disable (SRWD) bit in status register, combined > + with the WP# signal, provides hardware data protection for the device. When > + the SRWD bit is set to 1, and the WP# signal is either driven LOW or hard > + strapped to LOW, the status register nonvolatile bits become read-only and > + the WRITE STATUS REGISTER operation will not execute. The only way to exit > + this hardware-protected mode is to drive WP# HIGH. If the WP# signal of the > + flash device is not connected or is wrongly tied to GND (that includes internal > + pull-downs) then status register permanently becomes read-only as the SRWD bit > + cannot be reset. This boolean flag can be used on such systems to avoid setting > + the SRWD bit while writing the status register. WP# signal hard strapped to GND > + can be a valid use case. > + > reset-gpios: > description: > A GPIO line connected to the RESET (active low) signal of the device. > -- > 2.17.1 >