diff mbox series

[RFC,19/20] dt-bindings: interrupt-controller: arm,versatile-fpga-irq: mark oxnas compatible as deprecated

Message ID 20230331-topic-oxnas-upstream-remove-v1-19-5bd58fd1dd1f@linaro.org
State Superseded
Headers show
Series ARM: oxnas support removal | expand

Commit Message

Neil Armstrong March 31, 2023, 8:34 a.m. UTC
Due to lack of maintainance and stall of development for a few years now,
and since no new features will ever be added upstream, mark the
OX810 and OX820 IRQ compatible as deprecated.

Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org>
---
 .../bindings/interrupt-controller/arm,versatile-fpga-irq.txt          | 4 +++-
 1 file changed, 3 insertions(+), 1 deletion(-)

Comments

Krzysztof Kozlowski April 3, 2023, 6:37 p.m. UTC | #1
On 31/03/2023 10:34, Neil Armstrong wrote:
> Due to lack of maintainance and stall of development for a few years now,
> and since no new features will ever be added upstream, mark the
> OX810 and OX820 IRQ compatible as deprecated.
> 
> Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org>
> ---


Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>

Best regards,
Krzysztof
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/interrupt-controller/arm,versatile-fpga-irq.txt b/Documentation/devicetree/bindings/interrupt-controller/arm,versatile-fpga-irq.txt
index 2a1d16bdf834..ea939f54c5eb 100644
--- a/Documentation/devicetree/bindings/interrupt-controller/arm,versatile-fpga-irq.txt
+++ b/Documentation/devicetree/bindings/interrupt-controller/arm,versatile-fpga-irq.txt
@@ -6,7 +6,7 @@  controllers are OR:ed together and fed to the CPU tile's IRQ input. Each
 instance can handle up to 32 interrupts.
 
 Required properties:
-- compatible: "arm,versatile-fpga-irq" or "oxsemi,ox810se-rps-irq"
+- compatible: "arm,versatile-fpga-irq"
 - interrupt-controller: Identifies the node as an interrupt controller
 - #interrupt-cells: The number of cells to define the interrupts.  Must be 1
   as the FPGA IRQ controller has no configuration options for interrupt
@@ -19,6 +19,8 @@  Required properties:
   the system till not make it possible for devices to request these
   interrupts.
 
+The "oxsemi,ox810se-rps-irq" compatible is deprecated.
+
 Example:
 
 pic: pic@14000000 {