On Tue, 18 Jan 2022, Jason Gerecke wrote: > These two values go hand-in-hand and must be valid for the driver to > behave correctly. We are currently lazy about updating the values and > rely on the "expected" code flow to take care of making sure they're > valid at the point they're needed. The "expected" flow changed somewhat > with commit f8b6a74719b5 ("HID: wacom: generic: Support multiple tools > per report"), however. This led to problems with the DTH-2452 due (in > part) to *all* contacts being fully processed -- even those past the > expected contact count. Specifically, the received count gets reset to > 0 once all expected fingers are processed, but not the expected count. > The rest of the contacts in the report are then *also* processed since > now the driver thinks we've only processed 0 of N expected contacts. > > Later commits such as 7fb0413baa7f (HID: wacom: Use "Confidence" flag to > prevent reporting invalid contacts) worked around the DTH-2452 issue by > skipping the invalid contacts at the end of the report, but this is not > a complete fix. The confidence flag cannot be relied on when a contact > is removed (see the following patch), and dealing with that condition > re-introduces the DTH-2452 issue unless we also address this contact > count laziness. By resetting expected and received counts at the same > time we ensure the driver understands that there are 0 more contacts > expected in the report. Similarly, we also make sure to reset the > received count if for some reason we're out of sync in the pre-report > phase. > > Link: https://github.com/linuxwacom/input-wacom/issues/288 > Fixes: f8b6a74719b5 ("HID: wacom: generic: Support multiple tools per report") > CC: stable@vger.kernel.org > Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> > Reviewed-by: Ping Cheng <ping.cheng@wacom.com> Both patches applied, thanks.
diff --git a/drivers/hid/wacom_wac.c b/drivers/hid/wacom_wac.c index 2a4cc39962e7..5978399ae7d2 100644 --- a/drivers/hid/wacom_wac.c +++ b/drivers/hid/wacom_wac.c @@ -2692,11 +2692,14 @@ static void wacom_wac_finger_pre_report(struct hid_device *hdev, hid_data->cc_index >= 0) { struct hid_field *field = report->field[hid_data->cc_index]; int value = field->value[hid_data->cc_value_index]; - if (value) + if (value) { hid_data->num_expected = value; + hid_data->num_received = 0; + } } else { hid_data->num_expected = wacom_wac->features.touch_max; + hid_data->num_received = 0; } } @@ -2724,6 +2727,7 @@ static void wacom_wac_finger_report(struct hid_device *hdev, input_sync(input); wacom_wac->hid_data.num_received = 0; + wacom_wac->hid_data.num_expected = 0; /* keep touch state for pen event */ wacom_wac->shared->touch_down = wacom_wac_finger_count_touches(wacom_wac);