Series | [v3,1/4] mfd: da9062: make register CONFIG_I writable | expand |
On 12/1/21 12:15 AM, Andrej Picej wrote: > Implement a method to change watchdog timeout configuration based on DT > binding ("dlg,wdt-sd"). There is a possibility to change the bahaviour > of watchdog reset. Setting WATCHDOG_SD bit enables SHUTDOWN mode, and > clearing it enables POWERDOWN mode on watchdog timeout. > > If no DT binding is specified the WATCHDOG_SD bit stays in default > configuration, not breaking behaviour of devices which might depend on > default fuse configuration. > > Note: This patch requires that the config register CONFIG_I is > configured as writable in the da9062 multi function device. > > Signed-off-by: Andrej Picej <andrej.picej@norik.com> > --- > Changes in v3: > - no changes > > Changes in v2: > - don't force the "reset" for all da9062-watchdog users, instead add DT > binding where the behavior can be selected > --- > drivers/watchdog/da9062_wdt.c | 25 +++++++++++++++++++++++++ > 1 file changed, 25 insertions(+) > > diff --git a/drivers/watchdog/da9062_wdt.c b/drivers/watchdog/da9062_wdt.c > index f02cbd530538..e342e9e50cb1 100644 > --- a/drivers/watchdog/da9062_wdt.c > +++ b/drivers/watchdog/da9062_wdt.c > @@ -85,8 +85,33 @@ static int da9062_wdt_start(struct watchdog_device *wdd) > { > struct da9062_watchdog *wdt = watchdog_get_drvdata(wdd); > unsigned int selector; > + unsigned int mask; > + u32 val; > int ret; > > + /* Configure what happens on watchdog timeout. Can be specified with > + * "dlg,wdt-sd" dt-binding (0 -> POWERDOWN, 1 -> SHUTDOWN). > + * If "dlg,wdt-sd" dt-binding is NOT set use the default. > + */ Please use standard multi-line comments. This is not the networking subsystem. Also, if you think this code should be here and not in the probe function, as suggested by Adam, please provide a rationale. Thanks, Guenter > + ret = device_property_read_u32(wdd->parent, "dlg,wdt-sd", &val); > + if (!ret) { > + if (val) > + /* Use da9062's SHUTDOWN mode */ > + mask = DA9062AA_WATCHDOG_SD_MASK; > + else > + /* Use da9062's POWERDOWN mode. */ > + mask = 0x0; > + > + ret = regmap_update_bits(wdt->hw->regmap, > + DA9062AA_CONFIG_I, > + DA9062AA_WATCHDOG_SD_MASK, > + mask); > + > + if (ret) > + dev_err(wdt->hw->dev, "failed to set wdt reset mode: %d\n", > + ret); > + } > + > selector = da9062_wdt_timeout_to_sel(wdt->wdtdev.timeout); > ret = da9062_wdt_update_timeout_register(wdt, selector); > if (ret) >
diff --git a/drivers/watchdog/da9062_wdt.c b/drivers/watchdog/da9062_wdt.c index f02cbd530538..e342e9e50cb1 100644 --- a/drivers/watchdog/da9062_wdt.c +++ b/drivers/watchdog/da9062_wdt.c @@ -85,8 +85,33 @@ static int da9062_wdt_start(struct watchdog_device *wdd) { struct da9062_watchdog *wdt = watchdog_get_drvdata(wdd); unsigned int selector; + unsigned int mask; + u32 val; int ret; + /* Configure what happens on watchdog timeout. Can be specified with + * "dlg,wdt-sd" dt-binding (0 -> POWERDOWN, 1 -> SHUTDOWN). + * If "dlg,wdt-sd" dt-binding is NOT set use the default. + */ + ret = device_property_read_u32(wdd->parent, "dlg,wdt-sd", &val); + if (!ret) { + if (val) + /* Use da9062's SHUTDOWN mode */ + mask = DA9062AA_WATCHDOG_SD_MASK; + else + /* Use da9062's POWERDOWN mode. */ + mask = 0x0; + + ret = regmap_update_bits(wdt->hw->regmap, + DA9062AA_CONFIG_I, + DA9062AA_WATCHDOG_SD_MASK, + mask); + + if (ret) + dev_err(wdt->hw->dev, "failed to set wdt reset mode: %d\n", + ret); + } + selector = da9062_wdt_timeout_to_sel(wdt->wdtdev.timeout); ret = da9062_wdt_update_timeout_register(wdt, selector); if (ret)
Implement a method to change watchdog timeout configuration based on DT binding ("dlg,wdt-sd"). There is a possibility to change the bahaviour of watchdog reset. Setting WATCHDOG_SD bit enables SHUTDOWN mode, and clearing it enables POWERDOWN mode on watchdog timeout. If no DT binding is specified the WATCHDOG_SD bit stays in default configuration, not breaking behaviour of devices which might depend on default fuse configuration. Note: This patch requires that the config register CONFIG_I is configured as writable in the da9062 multi function device. Signed-off-by: Andrej Picej <andrej.picej@norik.com> --- Changes in v3: - no changes Changes in v2: - don't force the "reset" for all da9062-watchdog users, instead add DT binding where the behavior can be selected --- drivers/watchdog/da9062_wdt.c | 25 +++++++++++++++++++++++++ 1 file changed, 25 insertions(+)