Jonathan Cameron Oct. 31, 2020, 6:48 p.m. UTC
From: Jonathan Cameron <Jonathan.Cameron@huawei.com>

This basically has same questions as for the afe4403.  We could combine
the two bindings, but as the drivers are separate and it would be a little
fiddly due to different buses let's keep the separating.
To repeat questions from the ti,afe4403 binding.

A few questions came up whilst converting this one.
1) What is actually required?
   - Checking Linux driver, interrupt is not, and the tx-supply could
     be supplied by a stub regulator as long as it's always on.
     As such I have reduced the required list to just compatible and reg.
2) What is the regulator called?
   - It's tx-supply in the binding doc, but the driver request tx_sup
     I've left this alone for now.  Andrew could you confirm what is
     intended for this?

Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Cc: Andrew F. Davis <afd@ti.com>
---
 .../bindings/iio/health/afe4404.txt           | 29 -----------
 .../bindings/iio/health/ti,afe4404.yaml       | 51 +++++++++++++++++++
 2 files changed, 51 insertions(+), 29 deletions(-)

Comments

Jonathan Cameron Nov. 28, 2020, 4:24 p.m. UTC | #1
On Sat, 31 Oct 2020 18:48:16 +0000
Jonathan Cameron <jic23@kernel.org> wrote:

> From: Jonathan Cameron <Jonathan.Cameron@huawei.com>

> 

> This basically has same questions as for the afe4403.  We could combine

> the two bindings, but as the drivers are separate and it would be a little

> fiddly due to different buses let's keep the separating.

> To repeat questions from the ti,afe4403 binding.

> 

> A few questions came up whilst converting this one.

> 1) What is actually required?

>    - Checking Linux driver, interrupt is not, and the tx-supply could

>      be supplied by a stub regulator as long as it's always on.

>      As such I have reduced the required list to just compatible and reg.

> 2) What is the regulator called?

>    - It's tx-supply in the binding doc, but the driver request tx_sup

>      I've left this alone for now.  Andrew could you confirm what is

>      intended for this?

> 

> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>

> Cc: Andrew F. Davis <afd@ti.com>

Applied. with the maintainer switched to me for now as Andrew's email is
bouncing.

Thanks,

Jonathan

> ---

>  .../bindings/iio/health/afe4404.txt           | 29 -----------

>  .../bindings/iio/health/ti,afe4404.yaml       | 51 +++++++++++++++++++

>  2 files changed, 51 insertions(+), 29 deletions(-)

> 

> diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt

> deleted file mode 100644

> index 0b52830a0d9c..000000000000

> --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt

> +++ /dev/null

> @@ -1,29 +0,0 @@

> -Texas Instruments AFE4404 Heart rate and Pulse Oximeter

> -

> -Required properties:

> - - compatible		: Should be "ti,afe4404".

> - - reg			: I2C address of the device.

> - - tx-supply		: Regulator supply to transmitting LEDs.

> - - interrupts		: The interrupt line the device ADC_RDY pin is

> -			  connected to. For details refer to,

> -			  ../interrupt-controller/interrupts.txt.

> -

> -Optional properties:

> - - reset-gpios		: GPIO used to reset the device.

> -			  For details refer to, ../gpio/gpio.txt.

> -

> -Example:

> -

> -&i2c2 {

> -	heart_mon@58 {

> -		compatible = "ti,afe4404";

> -		reg = <0x58>;

> -

> -		tx-supply = <&vbat>;

> -

> -		interrupt-parent = <&gpio1>;

> -		interrupts = <28 IRQ_TYPE_EDGE_RISING>;

> -

> -		reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;

> -	};

> -};

> diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml

> new file mode 100644

> index 000000000000..187b99b22312

> --- /dev/null

> +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml

> @@ -0,0 +1,51 @@

> +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)

> +%YAML 1.2

> +---

> +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml#

> +$schema: http://devicetree.org/meta-schemas/core.yaml#

> +

> +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter

> +

> +maintainers:

> +  - Andrew F. Davis <afd@ti.com>

> +

> +properties:

> +  compatible:

> +    const: ti,afe4403

> +

> +  reg:

> +    maxItems: 1

> +

> +  tx-supply:

> +    description: Supply to transmitting LEDs.

> +

> +  interrupts:

> +    maxItems: 1

> +    description: Connected to ADC_RDY pin.

> +

> +  reset-gpios: true

> +

> +additionalProperties: false

> +

> +required:

> +  - compatible

> +  - reg

> +

> +examples:

> +  - |

> +    #include <dt-bindings/gpio/gpio.h>

> +    #include <dt-bindings/interrupt-controller/irq.h>

> +    i2c {

> +        #address-cells = <1>;

> +        #size-cells = <0>;

> +

> +        heart_mon@58 {

> +            compatible = "ti,afe4404";

> +            reg = <0x58>;

> +            tx-supply = <&vbat>;

> +            interrupt-parent = <&gpio1>;

> +            interrupts = <28 IRQ_TYPE_EDGE_RISING>;

> +            reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;

> +        };

> +    };

> +...
Rob Herring Dec. 18, 2020, 7:42 p.m. UTC | #2
On Sat, Oct 31, 2020 at 1:51 PM Jonathan Cameron <jic23@kernel.org> wrote:
>

> From: Jonathan Cameron <Jonathan.Cameron@huawei.com>

>

> This basically has same questions as for the afe4403.  We could combine

> the two bindings, but as the drivers are separate and it would be a little

> fiddly due to different buses let's keep the separating.

> To repeat questions from the ti,afe4403 binding.

>

> A few questions came up whilst converting this one.

> 1) What is actually required?

>    - Checking Linux driver, interrupt is not, and the tx-supply could

>      be supplied by a stub regulator as long as it's always on.

>      As such I have reduced the required list to just compatible and reg.

> 2) What is the regulator called?

>    - It's tx-supply in the binding doc, but the driver request tx_sup

>      I've left this alone for now.  Andrew could you confirm what is

>      intended for this?

>

> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>

> Cc: Andrew F. Davis <afd@ti.com>

> ---

>  .../bindings/iio/health/afe4404.txt           | 29 -----------

>  .../bindings/iio/health/ti,afe4404.yaml       | 51 +++++++++++++++++++

>  2 files changed, 51 insertions(+), 29 deletions(-)

>

> diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt

> deleted file mode 100644

> index 0b52830a0d9c..000000000000

> --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt

> +++ /dev/null

> @@ -1,29 +0,0 @@

> -Texas Instruments AFE4404 Heart rate and Pulse Oximeter

> -

> -Required properties:

> - - compatible          : Should be "ti,afe4404".

> - - reg                 : I2C address of the device.

> - - tx-supply           : Regulator supply to transmitting LEDs.

> - - interrupts          : The interrupt line the device ADC_RDY pin is

> -                         connected to. For details refer to,

> -                         ../interrupt-controller/interrupts.txt.

> -

> -Optional properties:

> - - reset-gpios         : GPIO used to reset the device.

> -                         For details refer to, ../gpio/gpio.txt.

> -

> -Example:

> -

> -&i2c2 {

> -       heart_mon@58 {

> -               compatible = "ti,afe4404";

> -               reg = <0x58>;

> -

> -               tx-supply = <&vbat>;

> -

> -               interrupt-parent = <&gpio1>;

> -               interrupts = <28 IRQ_TYPE_EDGE_RISING>;

> -

> -               reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;

> -       };

> -};

> diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml

> new file mode 100644

> index 000000000000..187b99b22312

> --- /dev/null

> +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml

> @@ -0,0 +1,51 @@

> +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)

> +%YAML 1.2

> +---

> +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml#

> +$schema: http://devicetree.org/meta-schemas/core.yaml#

> +

> +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter

> +

> +maintainers:

> +  - Andrew F. Davis <afd@ti.com>

> +

> +properties:

> +  compatible:

> +    const: ti,afe4403


Typo here, which causes this warning:

Documentation/devicetree/bindings/iio/health/ti,afe4403.example.dt.yaml:
heart_mon@0: 'spi-max-frequency' does not match any of the regexes:
'pinctrl-[0-9]+'

Took me a minute staring at ti,afe4403.yaml to figure out what was happening.

Rob
Jonathan Cameron Dec. 30, 2020, 12:21 p.m. UTC | #3
On Fri, 18 Dec 2020 13:42:19 -0600
Rob Herring <robh+dt@kernel.org> wrote:

> On Sat, Oct 31, 2020 at 1:51 PM Jonathan Cameron <jic23@kernel.org> wrote:

> >

> > From: Jonathan Cameron <Jonathan.Cameron@huawei.com>

> >

> > This basically has same questions as for the afe4403.  We could combine

> > the two bindings, but as the drivers are separate and it would be a little

> > fiddly due to different buses let's keep the separating.

> > To repeat questions from the ti,afe4403 binding.

> >

> > A few questions came up whilst converting this one.

> > 1) What is actually required?

> >    - Checking Linux driver, interrupt is not, and the tx-supply could

> >      be supplied by a stub regulator as long as it's always on.

> >      As such I have reduced the required list to just compatible and reg.

> > 2) What is the regulator called?

> >    - It's tx-supply in the binding doc, but the driver request tx_sup

> >      I've left this alone for now.  Andrew could you confirm what is

> >      intended for this?

> >

> > Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>

> > Cc: Andrew F. Davis <afd@ti.com>

> > ---

> >  .../bindings/iio/health/afe4404.txt           | 29 -----------

> >  .../bindings/iio/health/ti,afe4404.yaml       | 51 +++++++++++++++++++

> >  2 files changed, 51 insertions(+), 29 deletions(-)

> >

> > diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt

> > deleted file mode 100644

> > index 0b52830a0d9c..000000000000

> > --- a/Documentation/devicetree/bindings/iio/health/afe4404.txt

> > +++ /dev/null

> > @@ -1,29 +0,0 @@

> > -Texas Instruments AFE4404 Heart rate and Pulse Oximeter

> > -

> > -Required properties:

> > - - compatible          : Should be "ti,afe4404".

> > - - reg                 : I2C address of the device.

> > - - tx-supply           : Regulator supply to transmitting LEDs.

> > - - interrupts          : The interrupt line the device ADC_RDY pin is

> > -                         connected to. For details refer to,

> > -                         ../interrupt-controller/interrupts.txt.

> > -

> > -Optional properties:

> > - - reset-gpios         : GPIO used to reset the device.

> > -                         For details refer to, ../gpio/gpio.txt.

> > -

> > -Example:

> > -

> > -&i2c2 {

> > -       heart_mon@58 {

> > -               compatible = "ti,afe4404";

> > -               reg = <0x58>;

> > -

> > -               tx-supply = <&vbat>;

> > -

> > -               interrupt-parent = <&gpio1>;

> > -               interrupts = <28 IRQ_TYPE_EDGE_RISING>;

> > -

> > -               reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;

> > -       };

> > -};

> > diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml

> > new file mode 100644

> > index 000000000000..187b99b22312

> > --- /dev/null

> > +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml

> > @@ -0,0 +1,51 @@

> > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)

> > +%YAML 1.2

> > +---

> > +$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml#

> > +$schema: http://devicetree.org/meta-schemas/core.yaml#

> > +

> > +title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter

> > +

> > +maintainers:

> > +  - Andrew F. Davis <afd@ti.com>

> > +

> > +properties:

> > +  compatible:

> > +    const: ti,afe4403  

> 

> Typo here, which causes this warning:

> 

> Documentation/devicetree/bindings/iio/health/ti,afe4403.example.dt.yaml:

> heart_mon@0: 'spi-max-frequency' does not match any of the regexes:

> 'pinctrl-[0-9]+'

> 

> Took me a minute staring at ti,afe4403.yaml to figure out what was happening.

Doh!

Patch on it's way.

Thanks,

Jonathan

> 

> Rob
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt
deleted file mode 100644
index 0b52830a0d9c..000000000000
--- a/Documentation/devicetree/bindings/iio/health/afe4404.txt
+++ /dev/null
@@ -1,29 +0,0 @@ 
-Texas Instruments AFE4404 Heart rate and Pulse Oximeter
-
-Required properties:
- - compatible		: Should be "ti,afe4404".
- - reg			: I2C address of the device.
- - tx-supply		: Regulator supply to transmitting LEDs.
- - interrupts		: The interrupt line the device ADC_RDY pin is
-			  connected to. For details refer to,
-			  ../interrupt-controller/interrupts.txt.
-
-Optional properties:
- - reset-gpios		: GPIO used to reset the device.
-			  For details refer to, ../gpio/gpio.txt.
-
-Example:
-
-&i2c2 {
-	heart_mon@58 {
-		compatible = "ti,afe4404";
-		reg = <0x58>;
-
-		tx-supply = <&vbat>;
-
-		interrupt-parent = <&gpio1>;
-		interrupts = <28 IRQ_TYPE_EDGE_RISING>;
-
-		reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;
-	};
-};
diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml
new file mode 100644
index 000000000000..187b99b22312
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/health/ti,afe4404.yaml
@@ -0,0 +1,51 @@ 
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/health/ti,afe4404.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Texas Instruments AFE4404 Heart rate and Pulse Oximeter
+
+maintainers:
+  - Andrew F. Davis <afd@ti.com>
+
+properties:
+  compatible:
+    const: ti,afe4403
+
+  reg:
+    maxItems: 1
+
+  tx-supply:
+    description: Supply to transmitting LEDs.
+
+  interrupts:
+    maxItems: 1
+    description: Connected to ADC_RDY pin.
+
+  reset-gpios: true
+
+additionalProperties: false
+
+required:
+  - compatible
+  - reg
+
+examples:
+  - |
+    #include <dt-bindings/gpio/gpio.h>
+    #include <dt-bindings/interrupt-controller/irq.h>
+    i2c {
+        #address-cells = <1>;
+        #size-cells = <0>;
+
+        heart_mon@58 {
+            compatible = "ti,afe4404";
+            reg = <0x58>;
+            tx-supply = <&vbat>;
+            interrupt-parent = <&gpio1>;
+            interrupts = <28 IRQ_TYPE_EDGE_RISING>;
+            reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;
+        };
+    };
+...