diff mbox series

scsi: ufs: Fix NOP OUT timeout value

Message ID 231786897.01599016081767.JavaMail.epsvc@epcpadp2
State New
Headers show
Series scsi: ufs: Fix NOP OUT timeout value | expand

Commit Message

Daejun Park Sept. 2, 2020, 2:58 a.m. UTC
In some Samsung UFS devices, there is some booting fail issue with
low-power UFS device. The reason of this issue is the UFS device has a
little bit longer latency for NOP OUT response. It causes booting fail
because NOP OUT command is issued during initialization to check whether
the device transport protocol is ready or not. This issue is resolved by
releasing NOP_OUT_TIMEOUT value.

NOP_OUT_TIMEOUT: 30ms -> 50ms

Signed-off-by: Daejun Park <daejun7.park@samsung.com>
---
 drivers/scsi/ufs/ufshcd.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

Comments

Avri Altman Sept. 15, 2020, 6:35 a.m. UTC | #1
> 

> 

> In some Samsung UFS devices, there is some booting fail issue with

> low-power UFS device. The reason of this issue is the UFS device has a

> little bit longer latency for NOP OUT response. It causes booting fail

> because NOP OUT command is issued during initialization to check whether

> the device transport protocol is ready or not. This issue is resolved by

> releasing NOP_OUT_TIMEOUT value.

> 

> NOP_OUT_TIMEOUT: 30ms -> 50ms

> 

> Signed-off-by: Daejun Park <daejun7.park@samsung.com>

Acked-by: Avri Altman <avri.altman@wdc.com>
Daejun Park Sept. 15, 2020, 7:08 a.m. UTC | #2
Hi Avri,

> > In some Samsung UFS devices, there is some booting fail issue with

> > low-power UFS device. The reason of this issue is the UFS device has a

> > little bit longer latency for NOP OUT response. It causes booting fail

> > because NOP OUT command is issued during initialization to check whether

> > the device transport protocol is ready or not. This issue is resolved by

> > releasing NOP_OUT_TIMEOUT value.

> > 

> > NOP_OUT_TIMEOUT: 30ms -> 50ms

> > 

> > Signed-off-by: Daejun Park <daejun7.park@samsung.com>

> Acked-by: Avri Altman <avri.altman@wdc.com>


Thanks for the review.

Bart,
Could you review this patch, please?

Thanks,
Daejun
Martin K. Petersen Sept. 16, 2020, 12:14 a.m. UTC | #3
Daejun,

> In some Samsung UFS devices, there is some booting fail issue with

> low-power UFS device. The reason of this issue is the UFS device has a

> little bit longer latency for NOP OUT response. It causes booting fail

> because NOP OUT command is issued during initialization to check whether

> the device transport protocol is ready or not. This issue is resolved by

> releasing NOP_OUT_TIMEOUT value.


Applied to 5.10/scsi-staging, thanks!

-- 
Martin K. Petersen	Oracle Linux Engineering
Martin K. Petersen Sept. 22, 2020, 3:56 a.m. UTC | #4
On Wed, 02 Sep 2020 11:58:52 +0900, Daejun Park wrote:

> In some Samsung UFS devices, there is some booting fail issue with

> low-power UFS device. The reason of this issue is the UFS device has a

> little bit longer latency for NOP OUT response. It causes booting fail

> because NOP OUT command is issued during initialization to check whether

> the device transport protocol is ready or not. This issue is resolved by

> releasing NOP_OUT_TIMEOUT value.

> 

> [...]


Applied to 5.10/scsi-queue, thanks!

[1/1] scsi: ufs: Fix NOP OUT timeout value
      https://git.kernel.org/mkp/scsi/c/782e2efb749f

-- 
Martin K. Petersen	Oracle Linux Engineering
diff mbox series

Patch

diff --git a/drivers/scsi/ufs/ufshcd.c b/drivers/scsi/ufs/ufshcd.c
index 06e2439d523c..5cbd0e9e4ef8 100644
--- a/drivers/scsi/ufs/ufshcd.c
+++ b/drivers/scsi/ufs/ufshcd.c
@@ -36,8 +36,8 @@ 
 
 /* NOP OUT retries waiting for NOP IN response */
 #define NOP_OUT_RETRIES    10
-/* Timeout after 30 msecs if NOP OUT hangs without response */
-#define NOP_OUT_TIMEOUT    30 /* msecs */
+/* Timeout after 50 msecs if NOP OUT hangs without response */
+#define NOP_OUT_TIMEOUT    50 /* msecs */
 
 /* Query request retries */
 #define QUERY_REQ_RETRIES 3