On 7/9/20 2:35 PM, Rob Herring wrote: > On Tue, Jul 07, 2020 at 04:29:12PM -0500, Ricardo Rivera-Matos wrote: >> From: Dan Murphy <dmurphy@ti.com> >> >> Convert the battery.txt file to yaml and fix up the examples. >> >> Signed-off-by: Dan Murphy <dmurphy@ti.com> >> --- >> .../bindings/power/supply/battery.txt | 86 +--------- >> .../bindings/power/supply/battery.yaml | 157 ++++++++++++++++++ >> 2 files changed, 158 insertions(+), 85 deletions(-) >> create mode 100644 Documentation/devicetree/bindings/power/supply/battery.yaml >> >> diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt >> index 5e29595edd74..a9f80cc49068 100644 >> --- a/Documentation/devicetree/bindings/power/supply/battery.txt >> +++ b/Documentation/devicetree/bindings/power/supply/battery.txt >> @@ -1,87 +1,3 @@ >> -Battery Characteristics >> - >> -The devicetree battery node provides static battery characteristics. >> -In smart batteries, these are typically stored in non-volatile memory >> -on a fuel gauge chip. The battery node should be used where there is >> -no appropriate non-volatile memory, or it is unprogrammed/incorrect. >> - >> -Upstream dts files should not include battery nodes, unless the battery >> -represented cannot easily be replaced in the system by one of a >> -different type. This prevents unpredictable, potentially harmful, >> -behavior should a replacement that changes the battery type occur >> -without a corresponding update to the dtb. >> +The contents of this file has been moved to battery.yaml >> >> Please note that not all charger drivers respect all of the properties. >> - >> -Required Properties: >> - - compatible: Must be "simple-battery" >> - >> -Optional Properties: >> - - over-voltage-threshold-microvolt: battery over-voltage limit >> - - re-charge-voltage-microvolt: limit to automatically start charging again >> - - voltage-min-design-microvolt: drained battery voltage >> - - voltage-max-design-microvolt: fully charged battery voltage >> - - energy-full-design-microwatt-hours: battery design energy >> - - charge-full-design-microamp-hours: battery design capacity >> - - trickle-charge-current-microamp: current for trickle-charge phase >> - - precharge-current-microamp: current for pre-charge phase >> - - precharge-upper-limit-microvolt: limit when to change to constant charging >> - - charge-term-current-microamp: current for charge termination phase >> - - constant-charge-current-max-microamp: maximum constant input current >> - - constant-charge-voltage-max-microvolt: maximum constant input voltage >> - - factory-internal-resistance-micro-ohms: battery factory internal resistance >> - - ocv-capacity-table-0: An array providing the open circuit voltage (OCV) >> - of the battery and corresponding battery capacity percent, which is used >> - to look up battery capacity according to current OCV value. And the open >> - circuit voltage unit is microvolt. >> - - ocv-capacity-table-1: Same as ocv-capacity-table-0 >> - ...... >> - - ocv-capacity-table-n: Same as ocv-capacity-table-0 >> - - ocv-capacity-celsius: An array containing the temperature in degree Celsius, >> - for each of the battery capacity lookup table. The first temperature value >> - specifies the OCV table 0, and the second temperature value specifies the >> - OCV table 1, and so on. >> - - resistance-temp-table: An array providing the temperature in degree Celsius >> - and corresponding battery internal resistance percent, which is used to look >> - up the resistance percent according to current temperature to get a accurate >> - batterty internal resistance in different temperatures. >> - >> -Battery properties are named, where possible, for the corresponding >> -elements in enum power_supply_property, defined in >> -https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/include/linux/power_supply.h >> - >> -Batteries must be referenced by chargers and/or fuel-gauges >> -using a phandle. The phandle's property should be named >> -"monitored-battery". >> - >> -Example: >> - >> - bat: battery { >> - compatible = "simple-battery"; >> - voltage-min-design-microvolt = <3200000>; >> - voltage-max-design-microvolt = <4200000>; >> - energy-full-design-microwatt-hours = <5290000>; >> - charge-full-design-microamp-hours = <1430000>; >> - precharge-current-microamp = <256000>; >> - charge-term-current-microamp = <128000>; >> - constant-charge-current-max-microamp = <900000>; >> - constant-charge-voltage-max-microvolt = <4200000>; >> - factory-internal-resistance-micro-ohms = <250000>; >> - ocv-capacity-celsius = <(-10) 0 10>; >> - ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...; >> - ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...; >> - ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...; >> - resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>; >> - }; >> - >> - charger: charger@11 { >> - .... >> - monitored-battery = <&bat>; >> - ... >> - }; >> - >> - fuel_gauge: fuel-gauge@22 { >> - .... >> - monitored-battery = <&bat>; >> - ... >> - }; >> diff --git a/Documentation/devicetree/bindings/power/supply/battery.yaml b/Documentation/devicetree/bindings/power/supply/battery.yaml >> new file mode 100644 >> index 000000000000..0b3fc8cc6163 >> --- /dev/null >> +++ b/Documentation/devicetree/bindings/power/supply/battery.yaml >> @@ -0,0 +1,157 @@ >> +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) >> +%YAML 1.2 >> +--- >> +$id: http://devicetree.org/schemas/power/supply/battery.yaml# >> +$schema: http://devicetree.org/meta-schemas/core.yaml# >> + >> +title: Battery Characteristics >> + >> +maintainers: >> + - Sebastian Reichel <sre@kernel.org> >> + >> +description: | >> + The devicetree battery node provides static battery characteristics. >> + In smart batteries, these are typically stored in non-volatile memory >> + on a fuel gauge chip. The battery node should be used where there is >> + no appropriate non-volatile memory, or it is unprogrammed/incorrect. >> + >> + Upstream dts files should not include battery nodes, unless the battery >> + represented cannot easily be replaced in the system by one of a >> + different type. This prevents unpredictable, potentially harmful, >> + behavior should a replacement that changes the battery type occur >> + without a corresponding update to the dtb. >> + >> + Battery properties are named, where possible, for the corresponding elements >> + in enum power_supply_property, defined in include/linux/power_supply.h >> + >> + Batteries must be referenced by chargers and/or fuel-gauges using a phandle. >> + The phandle's property should be named "monitored-battery". >> + >> +properties: >> + compatible: >> + const: simple-battery >> + >> + over-voltage-threshold-microvolt: >> + description: battery over-voltage limit >> + >> + re-charge-voltage-microvolt: >> + description: limit to automatically start charging again >> + >> + voltage-min-design-microvolt: >> + description: drained battery voltage >> + >> + voltage-max-design-microvolt: >> + description: fully charged battery voltage >> + >> + energy-full-design-microwatt-hours: >> + description: battery design energy >> + >> + charge-full-design-microamp-hours: >> + description: battery design capacity >> + >> + trickle-charge-current-microamp: >> + description: current for trickle-charge phase >> + >> + precharge-current-microamp: >> + description: current for pre-charge phase >> + >> + precharge-upper-limit-microvolt: >> + description: limit when to change to constant charging >> + >> + charge-term-current-microamp: >> + description: current for charge termination phase >> + >> + constant-charge-current-max-microamp: >> + description: maximum constant input current >> + >> + constant-charge-voltage-max-microvolt: >> + description: maximum constant input voltage >> + >> + factory-internal-resistance-micro-ohms: >> + description: battery factory internal resistance >> + >> + monitored-battery: >> + $ref: /schemas/types.yaml#/definitions/phandle >> + description: phandle to the battery node being monitored > This needs to be a separate schema because it doesn't apply to > simple-battery nodes. This will have to wait for a future patch. The purpose of this patch is to convert battery.txt to yaml. > >> + >> +required: >> + - compatible >> + >> +patternProperties: >> + '^ocv-capacity-table-[0-100]$': >> + $ref: /schemas/types.yaml#/definitions/uint32-matrix >> + description: | >> + An array providing the open circuit voltage (OCV) >> + of the battery and corresponding battery capacity percent, which is used >> + to look up battery capacity according to current OCV value. And the open >> + circuit voltage unit is microvolt. >> + maxItems: 100 >> + items: >> + items: >> + - description: open circuit voltage (OCV) in microvolts >> + - description: battery capacity percent >> + maximum: 100 >> + >> + '^resistance-temp-table-[0-100]$': >> + $ref: /schemas/types.yaml#/definitions/uint32-matrix >> + description: | >> + An array providing the temperature in degree Celsius >> + and corresponding battery internal resistance percent, which is used to >> + look up the resistance percent according to current temperature to get an >> + accurate batterty internal resistance in different temperatures. >> + maxItems: 100 >> + items: >> + items: >> + - description: internal resistance percent >> + - description: battery capacity percent >> + maximum: 100 >> + >> + '^ocv-capacity-celsius-[0-100]$': >> + $ref: /schemas/types.yaml#/definitions/uint32-array >> + description: | >> + An array containing the temperature in degree Celsius, >> + for each of the battery capacity lookup table. >> + maxItems: 100 > This doesn't seem right. You can have a 100 tuples or just 2 u32's? If > the former, the type here should also be uint32-matrix. For the latter, > drop this and the first 'items'. ACK. I will change it to the former. > >> + items: >> + items: >> + - description: temperature in degree Celsius >> + - description: battery capacity percent >> + maximum: 100 >> + >> +additionalProperties: false >> + >> +examples: >> + - | >> + power { >> + #address-cells = <1>; >> + #size-cells = <0>; >> + >> + battery:battery { > space ^ ACK > >> + compatible = "simple-battery"; >> + over-voltage-threshold-microvolt = <4500000>; >> + re-charge-voltage-microvolt = <250000>; >> + voltage-min-design-microvolt = <3200000>; >> + voltage-max-design-microvolt = <4200000>; >> + energy-full-design-microwatt-hours = <5290000>; >> + charge-full-design-microamp-hours = <1430000>; >> + precharge-current-microamp = <256000>; >> + precharge-upper-limit-microvolt = <2500000>; >> + charge-term-current-microamp = <128000>; >> + constant-charge-current-max-microamp = <900000>; >> + constant-charge-voltage-max-microvolt = <4200000>; >> + factory-internal-resistance-micro-ohms = <250000>; >> + ocv-capacity-celsius-0 = <(-10) 10>; >> + ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>; >> + resistance-temp-table-0 = <20 100>, <10 90>, <0 80>, <(-10) 60>; >> + }; >> + >> + charger@11 { >> + reg = <0x11>; >> + monitored-battery = <&battery>; >> + }; >> + >> + fuel-gauge@22 { >> + reg = <0x22>; >> + monitored-battery = <&battery>; >> + }; >> + }; >> -- >> 2.27.0 >>
diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt index 5e29595edd74..a9f80cc49068 100644 --- a/Documentation/devicetree/bindings/power/supply/battery.txt +++ b/Documentation/devicetree/bindings/power/supply/battery.txt @@ -1,87 +1,3 @@ -Battery Characteristics - -The devicetree battery node provides static battery characteristics. -In smart batteries, these are typically stored in non-volatile memory -on a fuel gauge chip. The battery node should be used where there is -no appropriate non-volatile memory, or it is unprogrammed/incorrect. - -Upstream dts files should not include battery nodes, unless the battery -represented cannot easily be replaced in the system by one of a -different type. This prevents unpredictable, potentially harmful, -behavior should a replacement that changes the battery type occur -without a corresponding update to the dtb. +The contents of this file has been moved to battery.yaml Please note that not all charger drivers respect all of the properties. - -Required Properties: - - compatible: Must be "simple-battery" - -Optional Properties: - - over-voltage-threshold-microvolt: battery over-voltage limit - - re-charge-voltage-microvolt: limit to automatically start charging again - - voltage-min-design-microvolt: drained battery voltage - - voltage-max-design-microvolt: fully charged battery voltage - - energy-full-design-microwatt-hours: battery design energy - - charge-full-design-microamp-hours: battery design capacity - - trickle-charge-current-microamp: current for trickle-charge phase - - precharge-current-microamp: current for pre-charge phase - - precharge-upper-limit-microvolt: limit when to change to constant charging - - charge-term-current-microamp: current for charge termination phase - - constant-charge-current-max-microamp: maximum constant input current - - constant-charge-voltage-max-microvolt: maximum constant input voltage - - factory-internal-resistance-micro-ohms: battery factory internal resistance - - ocv-capacity-table-0: An array providing the open circuit voltage (OCV) - of the battery and corresponding battery capacity percent, which is used - to look up battery capacity according to current OCV value. And the open - circuit voltage unit is microvolt. - - ocv-capacity-table-1: Same as ocv-capacity-table-0 - ...... - - ocv-capacity-table-n: Same as ocv-capacity-table-0 - - ocv-capacity-celsius: An array containing the temperature in degree Celsius, - for each of the battery capacity lookup table. The first temperature value - specifies the OCV table 0, and the second temperature value specifies the - OCV table 1, and so on. - - resistance-temp-table: An array providing the temperature in degree Celsius - and corresponding battery internal resistance percent, which is used to look - up the resistance percent according to current temperature to get a accurate - batterty internal resistance in different temperatures. - -Battery properties are named, where possible, for the corresponding -elements in enum power_supply_property, defined in -https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/include/linux/power_supply.h - -Batteries must be referenced by chargers and/or fuel-gauges -using a phandle. The phandle's property should be named -"monitored-battery". - -Example: - - bat: battery { - compatible = "simple-battery"; - voltage-min-design-microvolt = <3200000>; - voltage-max-design-microvolt = <4200000>; - energy-full-design-microwatt-hours = <5290000>; - charge-full-design-microamp-hours = <1430000>; - precharge-current-microamp = <256000>; - charge-term-current-microamp = <128000>; - constant-charge-current-max-microamp = <900000>; - constant-charge-voltage-max-microvolt = <4200000>; - factory-internal-resistance-micro-ohms = <250000>; - ocv-capacity-celsius = <(-10) 0 10>; - ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...; - ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...; - ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...; - resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>; - }; - - charger: charger@11 { - .... - monitored-battery = <&bat>; - ... - }; - - fuel_gauge: fuel-gauge@22 { - .... - monitored-battery = <&bat>; - ... - }; diff --git a/Documentation/devicetree/bindings/power/supply/battery.yaml b/Documentation/devicetree/bindings/power/supply/battery.yaml new file mode 100644 index 000000000000..0b3fc8cc6163 --- /dev/null +++ b/Documentation/devicetree/bindings/power/supply/battery.yaml @@ -0,0 +1,157 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/power/supply/battery.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Battery Characteristics + +maintainers: + - Sebastian Reichel <sre@kernel.org> + +description: | + The devicetree battery node provides static battery characteristics. + In smart batteries, these are typically stored in non-volatile memory + on a fuel gauge chip. The battery node should be used where there is + no appropriate non-volatile memory, or it is unprogrammed/incorrect. + + Upstream dts files should not include battery nodes, unless the battery + represented cannot easily be replaced in the system by one of a + different type. This prevents unpredictable, potentially harmful, + behavior should a replacement that changes the battery type occur + without a corresponding update to the dtb. + + Battery properties are named, where possible, for the corresponding elements + in enum power_supply_property, defined in include/linux/power_supply.h + + Batteries must be referenced by chargers and/or fuel-gauges using a phandle. + The phandle's property should be named "monitored-battery". + +properties: + compatible: + const: simple-battery + + over-voltage-threshold-microvolt: + description: battery over-voltage limit + + re-charge-voltage-microvolt: + description: limit to automatically start charging again + + voltage-min-design-microvolt: + description: drained battery voltage + + voltage-max-design-microvolt: + description: fully charged battery voltage + + energy-full-design-microwatt-hours: + description: battery design energy + + charge-full-design-microamp-hours: + description: battery design capacity + + trickle-charge-current-microamp: + description: current for trickle-charge phase + + precharge-current-microamp: + description: current for pre-charge phase + + precharge-upper-limit-microvolt: + description: limit when to change to constant charging + + charge-term-current-microamp: + description: current for charge termination phase + + constant-charge-current-max-microamp: + description: maximum constant input current + + constant-charge-voltage-max-microvolt: + description: maximum constant input voltage + + factory-internal-resistance-micro-ohms: + description: battery factory internal resistance + + monitored-battery: + $ref: /schemas/types.yaml#/definitions/phandle + description: phandle to the battery node being monitored + +required: + - compatible + +patternProperties: + '^ocv-capacity-table-[0-100]$': + $ref: /schemas/types.yaml#/definitions/uint32-matrix + description: | + An array providing the open circuit voltage (OCV) + of the battery and corresponding battery capacity percent, which is used + to look up battery capacity according to current OCV value. And the open + circuit voltage unit is microvolt. + maxItems: 100 + items: + items: + - description: open circuit voltage (OCV) in microvolts + - description: battery capacity percent + maximum: 100 + + '^resistance-temp-table-[0-100]$': + $ref: /schemas/types.yaml#/definitions/uint32-matrix + description: | + An array providing the temperature in degree Celsius + and corresponding battery internal resistance percent, which is used to + look up the resistance percent according to current temperature to get an + accurate batterty internal resistance in different temperatures. + maxItems: 100 + items: + items: + - description: internal resistance percent + - description: battery capacity percent + maximum: 100 + + '^ocv-capacity-celsius-[0-100]$': + $ref: /schemas/types.yaml#/definitions/uint32-array + description: | + An array containing the temperature in degree Celsius, + for each of the battery capacity lookup table. + maxItems: 100 + items: + items: + - description: temperature in degree Celsius + - description: battery capacity percent + maximum: 100 + +additionalProperties: false + +examples: + - | + power { + #address-cells = <1>; + #size-cells = <0>; + + battery:battery { + compatible = "simple-battery"; + over-voltage-threshold-microvolt = <4500000>; + re-charge-voltage-microvolt = <250000>; + voltage-min-design-microvolt = <3200000>; + voltage-max-design-microvolt = <4200000>; + energy-full-design-microwatt-hours = <5290000>; + charge-full-design-microamp-hours = <1430000>; + precharge-current-microamp = <256000>; + precharge-upper-limit-microvolt = <2500000>; + charge-term-current-microamp = <128000>; + constant-charge-current-max-microamp = <900000>; + constant-charge-voltage-max-microvolt = <4200000>; + factory-internal-resistance-micro-ohms = <250000>; + ocv-capacity-celsius-0 = <(-10) 10>; + ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>; + resistance-temp-table-0 = <20 100>, <10 90>, <0 80>, <(-10) 60>; + }; + + charger@11 { + reg = <0x11>; + monitored-battery = <&battery>; + }; + + fuel-gauge@22 { + reg = <0x22>; + monitored-battery = <&battery>; + }; + };